User Guide
38 RH180 Manual
Water Filter Inspecon, Detecon & Cleaning
A. Inspecon:
To maintain opmum performance, periodically inspect the water lter.
To clean the water lter follow the cleaning procedure described in Step C.
If the water lter appears damaged, contact a qualied service provider for a replacement lter (Part No.
107000032)
B. Detecon:……..(Controller Flashing 07 or 63)
Flashing 07 is an indicaon that the water lter is dirty or restricng water ow thru the water heater.
Although the water heater will connue to operate the cleaning procedure described in Step C should be
performed as soon as possible.
Flashing 63 is an indicaon that the water lter is blocked and the appliance can no longer connue to
heat water. Follow the cleaning procedure described in Step C.
If the controller connues to ash the error code aer cleaning the water lter, turn o the unit and
contact a qualied service provider as this may indicate a pump error.
C. Cleaning:
1. Power OFF the water heater
Push the round power buon located on the right hand side of the controller.
Display will go blank when the power is o.
2. Remove the lower enclosure.
Remove the screws around the perimeter of the pump enclosure
Remove the enclosure by rst pulling away the boom poron.
3. Drain and Relieve pressure from the system
Close the cold water supply valve on the water heater
Open any hot water xture and leave open to allow draining
Aach one end of a hose to the drain valve and posion the other end of the hose at a near by drain.
4. Remove the lter by turning the thumb screw in a counterclockwise moon.
6. Clean the lter and remove any debris that may reduce water ow.
7. Replace the lter. Turn the thumb screw in clockwise direcon unl nger ght.
8. Close the drain valve and open the cold water supply valve leaving the hot water xture open unl all air
is out of the system
9. Power ON the water heater and set to desired temperature.
10. Close the hot water xture when nished.