Installation Manual
8
HE+ Series Infrared Gas Heater Installation and Operation Manual
TABLE 1B MINIMUM CLEARANCES TO COMBUSTIBLES
FIGURE 1B MINIMUM CLEARANCES TO COMBUSTIBLES - refer to Table 2 for values
*NOTE: Clearances are measured from the reflector.
The clearance to combustible materials represents the minimum distance that must be main-
tained between the heater and a nearby surface. The stated clearance to combustibles rep-
resents a surface temperature of 90F° (50C°) above room temperature.
NOTE: A ‘PEEL & STICK’ SIGN IS SUPPLIED: USE AN INDELIBLE MARKER TO ENTER
VALUES ‘H’, ‘S’, ‘F’, & ‘B’ ON THE SIGN.
POST THE SIGN ADJACENT TO THE HEATER THERMOSTAT OR IN A PROMI-
NENT LOCATION. See next page for details.
Input Rate
[BTUH]
SUSPENDED AT AN ANGLE
UP TO 45 DEGREES
SUSPENDED
HORIZONTALLY
D
inches (mm)
B
inches (mm)
F
inches (mm)
C
inches (mm)
A
inches (mm)
S
inches (mm)
C
inches (mm)
50,000 6 (152) 3 (76) 42 (1067) 46 (1168) 4 (102) 20 (508) 48 (1219)
65,000 6 (152) 3 (76) 50 (1270) 52 (1321) 4 (102) 22 (559) 54 (1372)
80,000 8 (203) 3 (76) 60 (1524) 64 (1626) 6 (152) 24 (610) 66 (1676)
115,000 10 (254) 3 (76) 66 (1676) 72 (1829) 6 (152) 28 (711) 78 (1981)
130,000 12 (305) 3 (76) 66 (1676) 72 (1829) 8 (203) 30 (762) 80 (2032)
155,000 12 (305) 4 (102) 72 (1829) 78 (1981) 8 (203) 32 (813) 84 (2134)
180,000 15 (381) 4 (102) 72 (1829) 78 (1981) 10 (254) 36 (914) 88 (2235)
205,000 15 (381) 6 (152) 80 (2032) 82 (2083) 10 (254) 40 (1016) 90 (2286)
225,000 18 (457) 6 (152) 82 (2083) 84 (2134) 15 (381) 44 (1118) 95 (2413)