Installation guide

4 | Compact 2 Installation Guide: 11817-A 01-12
Specication
Specification summary
Input = 9-25 MJ/h
Output = 1.6-5.0 kW
Efficiency = 73%
Heating area = up to 78 m²
Gas type = NG or LPG
Compact 2
Inbuilt radiant/convector, glass
fronted, ceramic log space heater
with forced convection and natural
draft flue system.
Burners
Ember bed and flame burner
Combustion system
Naturally aspirated multi port burner.
Data plate
Inside the appliance on the front right
hand side panel.
Fan
Convection fan tangential 2-speed.
Flue (masonry)
Refer page 9.
Flue (mock chimney)
Refer page 9.
Gas connection
½ “ BSPF male flare.
Gas control
Push button combination control
valve.
Glass types
- Primary: Ceramic glass
- Secondary: Tempered glass
- Glass seal material: Woven fibre
glass cord - Hytex
®
1000
- Log set: Ceramic
Ignition
Continuous spark electronic ignition.
Noise level
49 dB(A)
Operation
Push button to light pilot and burners
(low, medium, and high)
Power consumption
High = 20 W
Standby = 0 W
The electrical connection can exit the
appliance from the lower left or right
hand side, or from the rear of the
heater.
Safety devices
Flame failure thermocouple, overheat
switch (bi-metal strip), fan delay
(bi-metal strip), and power failure
protection
Weight
39 kg
25
All dimensions are in mm.
227
79
750
645
528
45
310
582
280
43