Location
The main points governing location are flueing and warm air distribution. The heater must
not be installed where curtains or other combustible materials could come into contact with
the appliance. In some cases curtains may need restraining.
Enclosure dimensions
The heater must be positioned on
a flat level surface that allows free
movement of the appliance.
- Masonry installations
Use a slurry of sand and
cement to level the base as
required.
- Mock chimney installations
The zero clearance box needs
to be supported. Either
construct a base using board
with supporting joists, or
support with the frame itself.
All dimensions provided are critical
to the installation of this appliance
and must be adhered to.
Mock chimney installations
When preparing a cavity/frame
for a zero clearance installation,
the total cavity depth MUST
also include the thickness of the
external cladding, as the zero
clearance box MUST BE installed
flush with the cladding surface.
Failure to do this will cause
misalignment of the flue system.
Masonry installation
Zero clearance (mock chimney) installation
Masonry Zero clearance
W-width 595-700 mm 685 mm
H-height 550-630 mm 615 mm
D-depth 360 mm* 380 mm
* Min clearance of spigot to back of fireplace is 50 mm