Technical Bulletin 121 - Activation Flow Rates at Higher Temperatures
Rinnai America Corporaon • 103 Internaonal Drive, Peachtree City, GA 30269
Toll-Free: 1-800-621-9419 • Phone: 678-829-1700 • www.rinnai.us
©2015 Rinnai America Corporaon. Rinnai America Corporaon connually updates materials, and as such, content is subject to change without noce. Local, state,
provincial, federal and naonal fuel gas codes must be adhered to prior to and upon installaon.
WARNING
Water temperature above 120°F (49° C) can cause serious injury. Mixing valve
temperature setting should be done by licensed contractor per local code
requirement. To ensure correct temperature control, use water thermometer at
faucet outlet.
The following dipswitch can be adjusted to opmize water ow acvaon rate when used in the following type
applicaons and the water heater temperature set point is greater than 135°F. The compable models of tankless
water heaters include the following series: VC, KB, KBD, KBP, KCM
High inlet (ground) water temperature
Hydronic applicaons
Hot water recirculaon
Acvate dip switch # 6 to achieve
temperatures higher than 120°F
Acvate dip switch # 7 to opmize water
ow acvaon rate when temperatures
of 135°F and/or higher are being used.