EXHAUST DUCTING OPTIONS
There are two ducting options available for this appliance, these are a Window installation or an optional Semi-
permanent wall installation.
IMPORTANT
DO NOT over extend the exhaust duct.
Over extension of the exhaust duct can lead to kinking.
Kinked ducting causes air ow restrictions and lowers the
eciency of the appliance.
Keeping the exhaust duct as short as possible avoids this
issue.
WINDOW INSTALLATIONS
The window kit has been designed to t most standard vertical and horizontal window applications. There may be 
some cases where you may need to modify some aspects of this installation procedure for certain window types. 
Minimum and maximum horizontal / vertical window opening dimensions:
1. Once a suitable window has been chosen, t the Adjustable Slider Kit (14) into the window areas and x the 
length of the kit using the supplied slide lock nut and bolt.
NOTE
It is recommended to place a length of foam draft sealing strip along the top and bottom edges of
the kit or the inside the window opening to form a seal.
2. Connect the Window Exhaust Duct Adaptor (15) to the Adjustable Slider Kit (14).
Foam seal
Insert window
exhaust duct
adaptor here
Slide lock nut and bolt
Horizontal
Window
Installation
A - Minimum = 675mm
A - Maximum = 1250mm
Vertical
Window
Installation
Window
Installation
kit
A
A
INSTALLATION