Models: RPC26MC RPC35MC Portable Room Air Conditioner Operation & Installation Manual REFRIGERANT R290
For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer’s instructions� Before proceeding with the operation of your new Rinnai Portable Room Air Conditioner, please read this manual thoroughly and gain a full understanding of the requirements, features and operation of your new appliance� REFRIGERANT R290 Rinnai 2 Portable Room AC OIM
TABLE OF CONTENTS Safety & Important Information 4 Specifications 10 Introduction ������������������������������������������������������������������������������������������������������������������������������������������������������� 10 Specifications ��������������������������������������������������������������������������������������������������������������������������������������������������� 10 Air Conditioner Basics 11 Appliance Components ��������������������������������������������������
SAFETY & IMPORTANT INFORMATION READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. WARNING Always comply with the following precautions to avoid dangerous situations and to ensure optimum performance. Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death. DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in personal injury or death.
SAFETY & IMPORTANT INFORMATION WARNING INFORMATION REGARDING APPLIANCES WITH R290 REFRIGERANT GAS WARNING Thoroughly read all of the warnings. This appliance contains up to 210g of R290 refrigerant gas. This appliance uses R290 refrigerant, which is class 3 flammability and must be handled by a refrigeration mechanic with appropriate Australian refrigerant handling licence. The appliance must be installed, used and stored in a ventilated area that is greater than 11 m2.
SAFETY & IMPORTANT INFORMATION EXPLANATION OF SYMBOLS DISPLAYED ON THE UNIT WARNING WARNING Risk of fire / flammable material. If the refrigerant is leaked, together with an external ignition source, there is a possibility of ignition. Read the OPERATING INSTRUCTIONS carefully before operation. Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.
SAFETY & IMPORTANT INFORMATION 6) No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
SAFETY & IMPORTANT INFORMATION 8. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer.
SAFETY & IMPORTANT INFORMATION 14. Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
SPECIFICATIONS INTRODUCTION This portable air conditioner can alter the room temperature and humidity. It has multiple functions of cooling dehumidifying (drying) and fan ventilation and can be moved from room to room and transported from building to building easily. The air conditioner can maintain set room indoor air temperatures between 16°C and 32°C. The set room temperature is displayed on the remote control and in the control panel on the unit.
AIR CONDITIONER BASICS APPLIANCE COMPONENTS 1 2 7 6 8 9 10 3 Front 5 Back 4 18 14 12 13 11 15 17 16 1. Control panel 2. Cool air outlet 3. Receiver window 4. Remote control 5. Exhaust outlet 6. Carry handles 7. Drain outlet 1 8. Drain outlet 2 (not used on this model) 9. Room air intake (filter located behind grill) 10. Lower air intake (filter located behind grill) 11. Swivel casters (x4) 12. Drain tray outlet 13. 1.
OPERATION CONTROL PANEL TEMP� Indicator 8 7 6 5 4 3 2 1. ON/OFF Button 2. Filter Reset Button 3. Fan Speed Button 4. Temperature Button 5. Mode Selection Button 6. Sleep Mode Button 7. Timer Button 8. Swing Button IMPORTANT 1 Before operating this appliance ensure that the location, installation and condensation requirements have been met, refer to installation instructions starting on page 19 for details.
OPERATION COOL 1. Press the ON/OFF (1) button. 2. Press the mode selection (5) button until the COOL mode indicator 3. Use temperature buttons (4) to select the desired temperature (16°C to 32°C) 4. Use fan speed button (3) to select the desired fan speed (AUTO, LOW, MED or HIGH). 5. Press the ON/OFF button (1) to stop operation. is illuminated. DRY 1. Press the ON/OFF (1) button. 2. Press the mode selection button (5) until the DRY mode indicator 3.
OPERATION TIMER With the appliance "OFF", press the "TIMER" button (7) once to active Delay On Timer. Press - or + to set the desired time period. Press the "TIMER" button 9&) again to lock in the setting. With the appliance "ON", press the "TIMER" button (7) once to active Delay Off Timer. Press - or + to set the desired time period. Press the "TIMER" button (7) again to lock in the setting. When a timer is set, pressing the "TIMER" button (7) will cancel any timer settings.
REMOTE CONTROL NOTE Before proceeding with the operation of your new Rinnai Portable Room Air Conditioner Remote Controller, please read these instructions thoroughly and gain a full understanding of the requirements features and operation of your new Remote Controller. Please keep the Operation and Installation Manual for your new Portable Room Air Conditioner handy so it can be referred to at any time in conjunction with these instructions. REMOTE CONTROL OVERVIEW 1. ON/OFF Button 2.
REMOTE CONTROL 6. “SLEEP” Button (a) In operating mode, press “SLEEP” to enter the 10-hour intelligent sleep mode. After 10 hours, the air conditioner will exit the sleep mode and restore its previous mode. (b) In sleep mode, press “SLEEP” again, or press “MODE” or “ON/OFF” to exit the sleep mode. NOTE The sleep mode cannot be started in fan only mode. 7. “FAN” button - Press “FAN” to start the Ventilation mode. 8. “COOL” button - Press “COOL” to start the Refrigeration mode. 9.
CARE & MAINTENANCE GENERAL MAINTENANCE It is recommended that after each cooling season the exterior panels and display of the appliance are cleaned with a soft damp cloth. 7 9 Air filters should be checked and cleaned every week during periods of heavy use. For intermittent use this can be extended to 2 to 3 weeks. 10 If storing the appliance for a prolong period remove the plugs and hoses from the drain outlets (7) , (8) and (12).
CARE & MAINTENANCE SAVE A SERVICE CALL SYMPTOM Appliance will not operate. POSSIBLE CAUSES POSSIBLE SOLUTIONS Not plugged into power. Plug into power. Power switch OFF. Switch power ON. Timer Function set. Wait or reset timer function. After switching off the appliance there may be a 3 minute delay before it may be re-started. Wait 3 minutes. Room temperature is lower than the set temperature. Adjust the set temperature to be lower than the room temperature. P1 appears on the display.
INSTALLATION LOCATION This portable air conditioner must be installed on a flat and dry surface. A minimum clearance of 500mm from walls or other appliances is required as well as easy access to a power point (GPO). mm The air outlets and the ducting system must not be obstructed. IMPORTANT mm 500 500 The appliance is fitted with a 1.2m flexible cord 220-240V 50Hz 10A. mm 500 The maximum duct extension is 1.8m in total.
INSTALLATION EXHAUST DUCTING OPTIONS There are two ducting options available for this appliance, these are a Window installation or an optional Semipermanent wall installation. DO NOT over extend the exhaust duct. IMPORTANT Over extension of the exhaust duct can lead to kinking. Kinked ducting causes air flow restrictions and lowers the efficiency of the appliance. Keeping the exhaust duct as short as possible avoids this issue.
INSTALLATION SEMI-PERMANENT WALL INSTALLATION In some cases a window opening might not be assessable; therefore Wall Exhaust Adaptor and Wall Exhaust Terminal are required that can be connected the Exhaust Duct. Note: Wall Exhaust Adaptor (PN 94320029) and Wall Exhaust Terminal (PN 94320031) are not supplied, please order separately.
WARRANTY TERMS OF WARRANTY – AUSTRALIA Rinnai Australia Pty. Ltd. ABN 74 005 138 769, 100 Atlantic Drive, Keysborough VIC 3173. NOTICE TO CONSUMERS UNDER AUSTRALIAN CONSUMER LAW Our goods and services come with guarantees that cannot be excluded under the Australian Consumer Law. For a major failure with a good, you are entitled to a replacement or refund and compensation for any other reasonable foreseeable loss or damage.
WARRANTY 2 TERMS OF WARRANTY 2.
WARRANTY 3 CONDITIONS OF WARRANTY 3.
WARRANTY 5 LIMITATIONS 5.1 Third parties are often involved in providing advice to consumers about the climate control solutions best suited to the consumer’s needs. Any advice or recommendations given by such parties, including advice about Product fitness for purpose and overall system design, sizing and application are not the responsibility of Rinnai. This includes but is not limited to the heat load calculations, airflow and system balancing. 5.
NOTES Rinnai 26 Portable Room AC OIM
NOTES Rinnai 27 Portable Room AC OIM
CONTACTS Rinnai Australia Pty Ltd ABN 74 005 138 769 | AU45204 100 Atlantic Drive, Keysborough, Victoria 3173 P.O. Box 460, Braeside, Victoria 3195 Tel: (03) 9271 6625 Fax: (03) 9271 6622 National Help Line Tel: 1300 555 545* Fax: 1300 555 655 Monday to Friday, 8.00 am to 5.00 pm EST. *Cost of a local call higher from mobile or public phones. For further information visit www.rinnai.com.au or email enquiry@rinnai.com.