Installation Guide
50 Rinnai Tankless Water Heater Installaon and Operaon Manual
4. Use the (Up) and (Down)
buons on the controller to
select a seng number (see
Parameter Sengs Table
below).
Certain elements of the installaon may require adjusng
the parameters of the tankless water heater.
To adjust the parameters:
1. Locate the PC Board (lower right side of unit).
2. Locate the two push buons (A and B) on the PC Board.
3. Press the “A” buon for 1 second.
5. Once the desired seng number is selected, use the
“On/O” buon on the controller to change the
selecon for the seng number.
Example: Display will change from 01A to 01b for
Maximum Temperature seng (as shown below).
6. To exit the parameters, press the “A” buon for 1 second.
SETTING
#
SETTING DESCRIPTION
SELECTION
A
c
01
Maximum Set Temperature 120° F 140° F
02
High Altude
(Installaon Locaon)
0 - 2,000
(0 - 610 m)
2,001 - 5,400
(610 - 1,646 m)
5,401 - 7,700
(1,646 - 2,347 m)
7,701 - 10,200
(2,347 - 3,109 m)
03
Service Soon
1
Disabled 0.5 Year 1 Year 2 Years
04
Recirculaon Sengs
No
Recirculaon
Recirculaon
(Dedicated)
05
Recirculaon Mode
2
Comfort Economy
06
Control Switch BMS
3
Air Handler (AH)
07
Units in Standby (EZ Connect) 2 1
10
Gas Type (Factory Set) NG LPG
11
Maximum Flow Rate
4
Standard High
12
Without Pump With Pump
Water Heater Model
(Factory set values and
not adjustable)
13
199 (3237) 180 (2934) 160 (2530) 130 (2024)
14
Internal (Indoor) External (Outdoor)
1
See secon “3.13 Service Indicator (Service Soon, 55)” for more informaon.
2
Seng 05 is available only if seng 04 is selected.
Comfort mode cycles the pump more frequently, ensuring the loop temperature remains higher (but also uses more
energy). Economy mode cycles the pump less oen, using less energy to maintain the circulaon loop temperature.
3
BMS = Building Management System
4
Selecng “High” will increase the water ow rate to the maximum capacity.
Parameter Sengs Table
DO NOT adjust parameter sengs
unless specically instructed to do so.
WARNING
3.12 Parameter Sengs
Default is A for all sengs below except 10, 12, 13, and 14 which are factory set.
0 1 A
0 1 B
A
B