Installation manual

Rinnai CVent 20
Installaon Instrucons
Back to back Conguraon (2 to 8 water heaters)
In Line Conguraon (2 to 8 water heaters)
Refer to the Ubbink appendix of this manual for the vent system assembly instrucons.
Follow these Rinnai installaon instrucons in this manual in addion to the Ubbink vent system assembly
instrucons.
Install the venng according to one of the 2 conguraons below. Do not locate the common vent remotely
from the water heaters.
The installaon area should be measured to make sure that adequate space is available to install the water
heaters and venng system.
NOTE: Dimensions above
are used in all back to back
configurations
Note: If water heaters are mounted directly on a wall, air intake piping will need to be in front of the appliance
adapters. The intake header in the drawing above has been removed for illustraon purposes.
TYPICAL
20.5” (520)
1”
(25mm)
2”
(51mm)
3”
(76mm)
EXHAUST
AIR
INTAKE
7”
(178mm)
6.25”
(159mm)
1”
(25mm)
2”
(51mm)
3”
(76mm)
4”
(101mm)
5”
(127mm)
6”
(152mm)
7”
(178mm)
TYPICAL
20.5” (520)
AIR
INTAKE
EXHAUST