Location
The main points governing location are ueing and warm air distribution. The heater must not
be installed where curtains or other combustible materials could come into contact with the
appliance. In some cases curtains may need restraining. Refer next page for clearance details.
The heater must be positioned on a at level surface. For installations further up the wall, the
heater needs to be supported, either construct a base using board or support with joists.
These are the minimum dimensions required if using the width, height
and depth dimensions above.
1100 - 1125 mm
850 mm min.
540 mm min.
1295 mm
1830 mm
915 mm
Enclosure
dimensions
Enclosure
dimensions in a
corner
The 540 mm minimum dimension will
give a 25 mm clearance (plus) from the
back of the unit.
A 25 mm clearance is required around the unit (sides and back).