Installation Manual
Rinnai Tankless Rack System (TRS) Installation Manual 49
ThermaCirc360 water heaters are factory set
for dedicated recirculaon.
A threaded cap and bypass plug assembly
are installed in the hot water outlet at the
base of the water heater.
For dedicated recirculaon, it is NOT
necessary to remove this plug.
04 Recirculaon Sengs
Dedicated Mode: Adjust parameter seng to 04 for dedicated recirculaon applicaons. Maximum
recirculaon loop length of 400 (122 m) with 3/4 in. pipe or 100 (30 m) with 1/2 in. pipe.
SETTING
#
SETTING
DESCRIPTION
SELECTION
A c
04
Recirculaon
Sengs
No
Recirculaon
Recirculaon
Dedicated Mode
Crossover Mode
Long Loop Short Loop
05
Recirculaon
Modes
Economy
Comfort
*Take equivalent elbow lengths into consideraon
when calculang pipe length.
Maximum Pipe Length*
Maximum pipe length includes the hot water supply line
and dedicated return line.
Pipe Diameter 3/4 in. 1/2 in.
Total 400 (122 m) 100 (30 m)
Refer to the Parameter Seng secon of the “Rinnai Tankless Water Heater Installaon and Operaon Manual” for
instrucons on accessing and changing parameter sengs.
05 Recirculaon Modes
• Economy (Factory Default): Adjust parameter seng to 05A for Economy mode. This mode cycles the pump
less oen, using less energy to maintain the circulaon loop temperature.
• Comfort: Adjust parameter seng to 05 for Comfort mode. This mode cycles the pump more frequently,
ensuring the loop temperature remains higher (but also uses more energy).
Configure TRW02ST and TRW03ST Racks for Dedicated Mode (Dedicated Recirculation Return Line) (Continued)
Plug/Filter Assembly (Dedicated Mode)
Parameter Sengs (Dedicated Mode)