Installation Manual
Rinnai Tankless Rack System (TRS) Installation Manual     37 
Vent  
Opons  
Vent Material  Diameter  
Max. 
Units  
Maximum  
Vent Length  
Exhaust  Intake  Header  Vent 
Common Vent 
Polypropylene  
or  
Schedule 40 
PVC/CPVC  
Polypropylene  
or  
Schedule 40 
PVC/CPVC  
3 in.   2  65 FT 
4 in.   4 
1-3 Units: 150 FT 
4 Units: 65 FT 
4 in.  6 in.  7 
1-6 Units: 150 FT 
7 Units: 70 FT 
6 in.   8  150 FT 
Concentric Pipe 
Polypropylene 
Schedule 40 
PVC  
5 in. 
1 
150 FT 
4 in.  65 FT 
Twin Pipe  
Polypropylene
3
or  
Schedule 40 
PVC/CPVC 
Schedule 40 
PVC/CPVC  
3 in. 
1  
150 FT 
2 in.  65 FT 
3 
Twin Pipe Polypropylene venng is provided by Centrotherm through their own distribuon network.  
Vent Opons for CU Series, SE Series, and SE+ Series Tankless Water Heaters 
The following table lists the vent opons for the CU Series, SE Series and SE+ Series tankless water heaters. 
HE+ Series tankless water heaters must use concentric venng with a metal exhaust pipe. Refer to the Installaon and 
Operaon Manual supplied with the HE+ Tankless Water Heater for venng opons.  
Vent Opons 