Rinnai Tankless Rack System (TRS) Installation Manual 49
ThermaCirc360 water heaters are factory set
for dedicated recirculaon.
A threaded cap and bypass plug assembly
are installed in the hot water outlet at the
base of the water heater.
For dedicated recirculaon, it is NOT
necessary to remove this plug.
04 Recirculaon Sengs
Dedicated Mode: Adjust parameter seng to 04 for dedicated recirculaon applicaons. Maximum
recirculaon loop length of 400  (122 m) with 3/4 in. pipe or 100  (30 m) with 1/2 in. pipe.
SETTING
#
SETTING
DESCRIPTION
SELECTION
A c
04
Recirculaon
Sengs
No
Recirculaon
Recirculaon
Dedicated Mode
Crossover Mode
Long Loop Short Loop
05
Recirculaon
Modes
Economy
Comfort
*Take equivalent elbow lengths into consideraon
when calculang pipe length.
Maximum Pipe Length*
Maximum pipe length includes the hot water supply line
and dedicated return line.
Pipe Diameter 3/4 in. 1/2 in.
Total 400  (122 m) 100  (30 m)
Refer to the Parameter Seng secon of the “Rinnai Tankless Water Heater Installaon and Operaon Manualfor
instrucons on accessing and changing parameter sengs.
05 Recirculaon Modes
Economy (Factory Default): Adjust parameter seng to 05A for Economy mode. This mode cycles the pump
less oen, using less energy to maintain the circulaon loop temperature.
Comfort: Adjust parameter seng to 05 for Comfort mode. This mode cycles the pump more frequently,
ensuring the loop temperature remains higher (but also uses more energy).
Configure TRW02ST and TRW03ST Racks for Dedicated Mode (Dedicated Recirculation Return Line) (Continued)
Plug/Filter Assembly (Dedicated Mode)
Parameter Sengs (Dedicated Mode)