Installation Manual
52 Rinnai Tankless Rack System (TRS) Installation Manual
Refer to the Parameter Seng secon of the “Rinnai Tankless Water Heater Installaon and Operaon Manual” for
instrucons on accessing and changing parameter sengs.
SETTING
#
SETTING
DESCRIPTION
SELECTION
A
c
04
Recirculaon
Sengs
No
Recirculaon
Recirculaon
Dedicated Mode
Crossover Mode
Long Loop Short Loop
05
Recirculaon
Modes
Economy Comfort
04 Recirculaon Sengs
Crossover Mode (Long Loop): Adjust parameter seng to 04C for loop length of 201 (60 m) to 400 (122 m)
with 3/4 in. pipe or for 51 (15 m) to 100 (30 m) with 1/2 in. pipe.
Crossover Mode (Short Loop): Adjust parameter seng to 04d for loop length of less than 200 (60 m) with 3/4
in. pipe or for less than 50 (15 m) with 1/2 in. pipe.
*Take equivalent
elbow lengths into
consideraon when
calculang pipe length.
Maximum Pipe Length*
Pipe Diameter 3/4 in. 1/2 in.
Short Loop
~200 (60 m) ~50 (15 m)
Long Loop 201 (60 m)~400 (122 m) 51 (15 m)~100 (30 m)
05 Recirculaon Modes
Economy (Factory Default): Adjust parameter seng to 05A for Economy mode. This mode cycles the pump less
oen, using less energy to maintain the circulaon loop temperature.
Comfort: Adjust parameter seng to 05 for Comfort mode. This mode cycles the pump more frequently,
ensuring the loop temperature remains higher (but also uses more energy).
Parameter Sengs (Crossover Mode)
Configure TRW02ST and TRW03ST Racks for Crossover Mode (Thermal Bypass Valve) (Continued)