Direct Vent Tankless Water Heater Installation and Operation Manual FOR INDOOR APPLICATIONS ONLY V94i ...................... REU-VC2837FFU-US V94Xi .................... REU-VC2737FFU-US V75i ...................... REU-VC2528FFU-US V65i ...................... REU-VC2025FFU-US FOR OUTDOOR APPLICATIONS ONLY V94e ..................... REU-VC2837W-US V75e ..................... REU-VC2528W-US V65e ..................... REU-VC2025W-US C US Low Lead Content NSF/ANSI 372 SANITATION ANS Z21.10.3 ● CSA 4.
Table of Contents Table of Contents ..................................................... 2 Safety Behaviors and Practices for the Consumer and Installer ............................................ 3 Installation Instructions (for the licensed professional) ............................. 4 Prepare for Installation ...................................... 5 Determine Installation Location ........................ 6 Freeze Protection .............................................
Safety Behaviors and Practices for the Consumer and Installer WARNING Before operating, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. Keep the area around the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Installation Instructions (for the licensed professional) Installer Qualifications General Instructions A licensed professional must install the appliance, inspect it, and leak test it before use. The warranty will be voided due to improper installation. DO NOT The installer should have skills such as: gas sizing connecting gas lines, water lines, valves, electricity, knowledge of applicable national, state, and local codes.
Prepare for Installation You must follow the installation instructions and those in Care and Maintenance for adequate combustion air intake and exhaust. INFORMATION Parts included Tankless water heater MC-91-2 temperature controller (integrated into If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the cold water supply line, means shall be provided to control thermal expansion.
Determine Installation Location You must ensure that clearances will be met and that the vent length will be within required limits. Consider the installation environment, water quality, and need for freeze protection. Requirements for the gas line, water lines, electrical connection, and condensate disposal can be found in their respective installation sections of this manual. Water Quality Consideration of care for your water heater should include evaluation of water quality.
Terminal Clearances For indoor models, you must install a vent termination to bring in combustion air and expel exhaust. X TERMINATION AIR SUPPLY INLET V VENT TERMINAL Clearance in Ref. A also applies to anticipated snow line AREA WHERE TERMINAL IS NOT PERMITTTED SNOW Ref A Description Clearance above grade, veranda, porch, deck, or balcony Direct Vent (Indoor Unit) Canadian Installations (CSA US Installations B149.1) (ANSI Z223.
Additional clearances - V94i, V94Xi, V75i, V65i Check on whether local codes supersede these clearances. Avoid termination locations near a dryer vent. Avoid termination locations near commercial 60" (1.52 m) between terminals at different levels V V cooking exhaust.
Additional clearances V94e, V75e, V65e Local codes supersede these clearances. Avoid termination locations near a dryer vent. Avoid termination locations near commercial cooking exhaust. (50 mm) between terminals at same level (0.91 m) to ventilated or unventilated 12" 2" 36" soffit or eve vent; or to a deck or porch (0.30 m) to an inside corner 60" (1.
Unit clearances Indoor models: V94i, V94Xi, V75i, V65i to Combustibles inches (mm) Outdoor models: V94e, V75e, V65e to NonCombustibles to Combustibles inches (mm) inches (mm) to NonCombustibles inches (mm) Top of Heater 6 * (152) 2 *(51) Top of Heater 12 (305) 2 (51) Back of Heater 0 (zero) 0 (zero) Back of Heater 0 (zero) 0 (zero) Front of Heater 6 (152) 6 (152) Front (Panel) 24 (610) 0 (zero) Sides of Heater 2 (51) 1/2 (13) Front (Exhaust) 24 (610) 24 (610) Ground/Bottom 12
Maximum vent length (indoor models only) Freeze Protection 1. Determine the number of 90 degree elbows in the vent system. (Two 45 degree elbows count as one 90 degree elbow.) 2. Refer to the table to find the maximum vent length based on the number of elbows. Number of 90° Elbows Maximum vent length 0 41 ft (12.5 m) 1 35 ft (10.7 m) 2 29 ft (8.8 m) 3 23 ft (7.0 m) 4 17 ft (5.2 m) 5 11 ft (3.4 m) 6 5 ft (1.
Checklist to Determine Installation Location Mount to Wall □ The water heater is not exposed to corrosive compounds in the air. □ The water heater location complies with the wall installation brackets clearances. □ For indoor models, the planned venting will not exceed the maximum length for the number of elbows used. □ The planned venting termination/air intake location meets the clearances. □ The water supply does not contain chemicals or exceed total hardness that will damage the heat exchanger.
Installation of Venting (indoor models only) Install the correct venting for your model according to the venting manufacturer’s instructions and the guidelines below. Refer to the manufacturer’s technical literature for specific part numbers and instructions. Manufacturer Listed and Tested Vent Products for V94i, V94Xi, V75i and V65i Telephone Fax Contact Ubbink Rolux Vent System 800-621-9419 678-829-1666 www.rinnai.us Heat-Fab Saf-T Vent SC system 800-772-0739 413-863-4803 custsvc@heat-fab.
Flue Installation (indoor models only) Install the venting termination according to the diagrams and instructions below. Horizontal Termination without using the Condensate Collector WARNING If the condensate collector is not used, the drain pipe must be capped to prevent exhaust gases and condensate from entering the building. The cap is supplied on the appliance. * The condensate collector must be used in horizontal terminations if a vertical rise in the vent system exceeds 5ft.
Condensate (indoor models only) Condensate formation can occur in high efficiency direct vent appliances. Without proper drainage condensate will damage the heat exchanger. To prevent condensate damage follow these instructions. INFORMATION A condensate trap is available, P/N 222053. Regions of cold climate will create more condensate in the vent system. The condensate collector should be used in cold climates.
Installation of Plumbing Pressure Relief Valve Requirements INFORMATION Install the pressure relief valve according to local plumbing codes and these instructions. If a relief valve discharges periodically, this may be An approved pressure relief valve is required by the American National Standard (ANSI Z21.10.3) for all water heating systems, and shall be accessible for servicing.
Piping Diagram for Basic Installation Rinnai Water Heater Rinnai Equipment List QTY Rinnai Water Heaters 1 RIK-KIT (Optional) 1 (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.
Installation of Gas Supply Connect Water Heater to Water Supply WARNING Water connections to the tankless water heater should follow all state and local plumbing codes. 1. A licensed professional must install the gas supply. If this is a standard installation, refer to the Piping Diagram for Basic Installation. 2. Turn off 120v power supply. 1. Plumb water supply to the tankless water heater on the 3/4” MNPT connection at the bottom of the unit marked “Water Inlet”, which is the cold water supply. 4.
Any compound used on the threaded joint of the gas piping shall be a type which resists the action of liquefied petroleum gas (propane / LPG). The gas supply line shall be gas tight, sized, and so installed as to provide a supply of gas sufficient to meet the maximum demand of the heater and all other gas consuming appliances at the location without loss of pressure. Schedule 40 Metallic Pipe Inlet Pressure: less than 2 psi (55 inches W.C.) Pressure Drop: 0.3 inches W.C. Specific Gravity: 0.
Connect Electricity Adjust for High Altitude WARNING Do not use an extension cord or an adapter plug with this appliance. The water heater must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, in accordance with the National Electrical Code, ANSI/NFPA 70. In DIPSW 1, set SW 2 and SW 3 to the values shown in table below for your altitude. The default setting for the appliance is 0-2000 ft (0-610 m) with SW 2 and SW 3 in the OFF position.
Installation of Temperature Controller WARNING Configurations Turn the power off. Do not attempt to connect the temperature controllers with the power on. Although the controller is a low voltage device, there is 120 volt potential next to the temperature controller connections inside the unit. Do not connect the temperature controller to the 120VAC terminals provided for the optional solenoid drain valves.
Mounting the controller 1. Make three holes in the wall as shown. Outline of Remote securing screw 1-21/32" wiring hole 3-5/16" securing screw 2. Run the cable between the controller and the water heater or the controller and another controller. 3. Remove the face plate from the temperature controller using a screwdriver. 4. Connect the cable to the temperature controller. 5. Mount the controller to the wall using the holes drilled in step 1. 6. Disconnect the power from the water heater. 7.
Final Checklist □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ The water heater is not subject to corrosive compounds in the air. The water supply does not contain chemicals or exceeds total hardness that will damage the heat exchanger. Clearances from the water heater unit are met. Clearances from the vent termination / air intake are met.
Technical Data Specifications V65i V75i V94Xi V94i Hot water capacity (Min - Max) * V75e V94e 150,000 180,000 199,000 10,300 Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h V65e 150,000 180,000 192,000 199,000 0.26 - 6.6 GPM 0.26 - 7.5 GPM 0.26 - 9.8 GPM 0.26 - 9.8 GPM 0.26 - 6.6 GPM 0.26 - 7.5 GPM 0.26 - 9.8 GPM (1.0 - 25.0 L/min) (1.0 - 28.5 L/min) (1.0 - 37.0 L/min) (1.0 - 37.0 L/min) (1.0 - 25.0 L/min) (1.0 - 28.5 L/min) (1.0 - 37.
Dimensions Inches (millimeters) V94i, V94Xi, V75i, V65i 9.27 (235.5) 14.04 (356.6) 0.4~1.8(10~45) Variable 2.67 (67.8) 5.05 (128.1) B 22.95 (583) C E F G D DIMENSION Inches (mm) DIMENSION Inches (mm) A (GAS) 1.31 (33.2) D 4.33 (110) A (COLD) 1.93 (49) E 2.89 (73.3) A (HOT) 1.35 (34.4) F 1.85 (47) B 4.21 (106.9) G 3.44 (87.3) C 1.17 (29.8) A 14.04 (356.6) 2.23 (56.6) V94e, V75e, V65e 0.28 (7.2) 9.27 (235.5) 0.59 (15) 1.14 (29) 8.90 (226) 22.
Pressure Drop Curve Pressure Loss (psi) Water Flow (gpm) Water Flow Curve V94i/e V94Xi Water Flow (gpm) V75i/e V65i/e delta T - Temperature Rise (°F) 26 V75i/e V94i/e V94Xi Pressure Loss (ft head) V65i/e Value Series Manual
Ladder Diagram Value Series Manual 27
Direct Vent Tankless Water Heater Operation Instructions FOR INDOOR APPLICATIONS ONLY V94i ...................... REU-VC2837FFU-US V94Xi .................... REU-VC2737FFU-US V75i ...................... REU-VC2528FFU-US V65i ...................... REU-VC2025FFU-US FOR OUTDOOR APPLICATIONS ONLY V94e ..................... REU-VC2837W-US V75e ..................... REU-VC2528W-US V65e .....................
Consumer Operation Guidelines for the Safe Operation of your Water Heater FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas.
How to use the Temperature Controller The MC-91-2 controller is the standard temperature controller that is supplied with the water heater. On indoor models it is integrated into the front panel. The MCC-91-2 controller is for hydronic applications requiring higher temperatures. When the MCC-91-2 controller is connected, these higher temperatures are available on all controller models in the system. Refer to the section on temperature ranges.
How to Set the Temperature This water heater requires a minimum flow rate to operate. This rate can be found on the specification page in this manual. In some cases when you are not getting hot water or if the water alternates between hot and cold, it is due to the water flow being below or close to the minimum flow rate. Increasing the flow rate should resolve these problems in these cases. If you are experiencing issues with higher temperature settings, then reduce the temperature setting.
Temperatures Available with a Controller The water heater can deliver water at only one temperature setting at a time. The available temperatures are provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water. To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” button for 5 seconds while the water heater is OFF.
Diagnostic Codes This water heater is designed to display diagnostic codes. If there is a potential operation concern refer to the code and remedy on the next page. To Display Diagnostic Information To display the most recent diagnostic codes press and hold the “On/Off” button for 2 seconds on the MC-91-2 controller. While holding the “On/Off” button press the up button. The last 9 diagnostic codes will flash one after the other. To exit this mode press the “On/Off” and up button as before.
Diagnostic Codes and Remedies WARNING Some of the checks below should be done by a licensed professional. Consumers should never attempt any action that they are not qualified to perform. Code Definition 03 Power interruption during Bath Fill (Water will not flow when power returns). Air Supply or Exhaust Blockage 10 Remedy Turn off all hot water taps. Press ON/OFF twice. Check that nothing is blocking the flue inlet or exhaust. Check all vent components for proper connections.
Code Definition Remedy 19 Electrical Grounding Check all components for electrical short. Outgoing Water Temperature Sensor Heat Exchanger Outgoing Temperature Sensor Check sensor wiring for damage. Measure resistance of sensor. Clean sensor of scale build-up. Replace sensor. 34 Combustion Air Temperature Sensor Fault Check for restrictions in air flow around unit and vent terminal. Check sensor wiring for damage. Measure resistance of sensor. Clean sensor of scale build-up.
Required Maintenance The appliance must be inspected annually by a licensed professional. Repairs and maintenance should be performed by a licensed professional. The licensed professional must verify proper operation after servicing. WARNING To protect yourself from harm, before performing maintenance: Turn off the electrical power supply by unplugging the power cord or by turning off the electricity at the circuit breaker. (The temperature controller does not control the electrical power.
catch any water that is contained inside the unit. Unscrew the water filter. Rinse the filter to remove any debris. Install the filter and open the isolation valves. drain down solenoid valves be purchased and installed that will automatically drain the unit if power is lost. These are available in a kit, 104000059. a surge protector with terminals be purchased WARNING Testing the pressure relief valve should only be performed by a licensed professional.
Flushing the Heat Exchanger An LC0~LC9 or “00” diagnostic code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s warranty. Rinnai strongly recommends installation of isolation valves to allow for flushing of the heat exchanger. KEY 1. Disconnect electrical power to the water heater. 2.
Manual Draining of the Water Heater WARNING To avoid burns, wait until the equipment cools down before draining the water. The water in the appliance will remain hot after it is turned off. If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained. To manually drain the water: 1. Shut off cold water supply and gas supply. 2. Turn off the temperature controller. 3. Disconnect the power to the water heater.
State Regulations NOTICE BEFORE INSTALLATION This direct-vent appliance must be installed by a licensed professional. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.
Replacement Parts The Technical Sheet which is located inside the front cover of the water heater contains a complete illustrated parts list. Gas Control Assembly Tech Sheet Item No.
Consumer Warranty Limited Warranty What is covered? This Limited Warranty covers any defects in materials or workmanship when the product is installed and operated according to Rinnai written installation instructions, subject to the terms within this Limited Warranty document. This Limited Warranty applies only to products that are installed correctly in the United States and Canada. Improper installation may void this Limited Warranty.
Proof of purchase is required to obtain warranty service. You may register this product within 30 days of purchase or you may show proof of purchase with a dated sales receipt. To register your tankless water heater, please visit www.rinnai.us. For those without internet access, please call 1-800-621-9419 . Receipt of Registration by Rinnai will constitute proof-of-purchase for this product. However, Registration is not necessary in order to validate this Warranty.
POUR LES APPLICATIONS INTÉRIEURES SEULEMENT Chauffe-eau d’intérieur sans réservoir à ventilation directe Manuel d'installation et d'utilisation V94i ........................ REU-VC2837FFU-US V94Xi ...................... REU-VC2737FFU-US V75i ........................ REU-VC2528FFU-US V65i ........................ REU-VC2025FFU-US POUR LES APPLICATIONS EXTÉRIEUR SEULEMENT V94e ....................... REU-VC2837W-US V75e ....................... REU-VC2528W-US V65e .......................
Table des matières Table des matières.................................................. 45 Les pratiques et les comportements de sécurité pour les consommateurs et les installateurs .................. 46 Installation d’instructions (pour le professionnel autorisé) ......................... 47 Préparez-vous à l'installation ........................ 48 Déterminez l'endroit d’installation................ 49 Protection de gel ...........................................
Les pratiques et les comportements de sécurité pour les consommateurs et les installateurs AVERTISSEMENT Avant la mise en œuvre, reniflez tout autour de la zone de l’appareil pour détecter une odeur de gaz. Ne manquez pas de chercher près du plancher car certains gaz sont plus lourds que l’air et s’accumulent au sol. Gardez la zone autour de l’appareil dégagée et exempte de matières combustibles, d’essence et d’autres vapeurs ou liquides inflammables.
Installation d’instructions (pour le professionnel autorisé) Qualifications d'installateur Instructions générales Un professionnel agréé doit installer l'appareil, inspecter et fuite de le tester avant des utiliser. La garantie sera être annulée en raison de la mauvaise installation.
Préparez-vous à l'installation L'appareil et sa vanne de gaz doivent être débranchés de la conduite d'alimentation en gaz durant les essais du système en pression dépassant 1/2 psi (3.5 kPa ou 13,84 pouces de hauteur de colonne d'eau).
Déterminez l'endroit d’installation Environnement Vous devez vous assurer que les habilitations seront satisfaites et que le cloaque sera dans les limites requises. Tenir compte de l'environnement d'installation, qualité de l'eau et nécessité d'une protection de gel. On trouvera des exigences pour la conduite de gaz, conduites d'eau, connexion électrique et d'élimination de condensat dans leurs sections respectives d'installation de ce manuel.
Dégagements à la terminaison Pour les modèles d’intérieur, vous devez installer une terminaison de ventilation pour faire entrer de l’air de combustion et dégager les gaz d’échappement. TERMINAISON TERMINATION X DÉTAIL D’ANGLE RENTRANT V LeClearance dégagement in en référence Ref.
Dégagements additionnels V94e, V75e, V65e Vérifier si les codes locaux remplacent ces habilitations. Éviter les endroits de résiliation près d'un évent sécheur. Évitez les endroits de résiliation près d'échappement cuisson commercial. (50 mm) entre terminaux au même niveau V94i, V94Xi, V75i, V65i: Vous devez installer une résiliation de vent au moins 12 pouces du sol.
Dégagements d'unité Vers le haut Vers le haut Sur le côté Sur le côté Vers l'avant Vers l'avant Vers le sol Vers le sol Modèles d'intérieur: V94i, V94Xi, V75i, V65i Jusqu'à matières combustibles pouces (mm) Modèles extérieurs: V94e, V75e, V65e Jusqu'à matières noncombustibles Jusqu'à matières combustibles pouces (mm) pouces (mm) Jusqu'à matières noncombustibles pouces (mm) Dessus du chauffe-eau 6 * (152) 2 *(51) Dessus du chauffe-eau 12 (305) 2 (51) Arrière du chauffe-eau 0 (zero) 0 (z
Longueur maximale de ventilation Protection de gel Longueur maximale de ventilation concentrique Assurez-vous que dans le cas de congélation météo que le chauffe-eau et ses lignes de l'eau sont protégés pour éviter le gel. Dommages causés à la congélation n'est pas couvert par la garantie. 1. Déterminez le nombre de coudes à 90 degrés dans le système de ventilation (Deux coudes à 45 degrés comptent comme un coude à 90 degrés). 2.
Liste de vérification pour déterminer l'endroit d’installation Bâti à murer □ Le chauffage de l'eau n'est pas corrosifs composés dans l'air. □ L'emplacement de chauffage de l'eau est parenthèses d'installation de mur conforme avec les dégagements. □ (Modèles d'intérieur) La ventilation prévue ne dépassera pas la longueur maximale pour le nombre de coudes utilisé. □ L'emplacement d'apport résiliation/air ventilation prévues réunit les dégagements.
Installation de la mise à l'air libre (modèles d'intérieur) Installez la ventilation correcte pour votre modèle, en suivant les instructions du fabricant de ventilation. Reportez-vous à la documentation technique du fabricant pour les numéros de pièce spécifiques et des instructions. Constructeur Produits de ventilation listés et testés (V94i, V94Xi, V75i, V65i) Téléphone Fax Contact Ubbink Rolux Vent System 888-835-9320 678-829-1666 www.rinnai.
Installation de conduit de cheminée (modèles d'intérieur) Résiliation horizontale sans utiliser le collecteur de condensat * Un collecteur de condensat est requis sur les terminaisons horizontales si une élévation verticale dans le système de ventilation dépasse 5' (1,5 m). AVERTISSEMENT Si un collecteur de condensat n'est pas utilisé, le tuyau de drainage doit être capuchonnée pour éviter que gaz d'échappement et condensat n'entrent dans le bâtiment. Ce capuchon est livré sur l'appareil.
Condensat (modèles d'intérieur) La formation de condensat peut arriver même sur les appareils à ventilation directe de haute performance. Pour éviter que le condensat n'endommage, suivez ces instructions. NE FAITES PAS L’INFORMATION Un piège à condensats est disponible, P / N 222053 Dans les régions à climat froid il se produira plus de condensat dans le système de ventilation. Un collecteur de condensat est recommandé climats. Ne permettent pas de condensat d'entrer dans le chauffe-eau.
Installation de la tuyauterie L’INFORMATION Si une soupape de sûreté déverse périodiquement, cela peut venir d'une expansion thermique dans un système d'eau fermé. Contactez votre fournisseur d'eau ou votre inspecteur de plomberie local pour voir comment régler cette situation. Mais ne bouchez pas la soupape. Soupape de sûreté Installez la soupape selon les codes de plomberie local et ces instructions. Une soupape de sûreté est nécessaire, d'un type approuvé par les normes américaines (ANSI Z21.10.
Tuyauterie recommandée pour installation de base Rinnai Water Heater Rinnai Equipment List QTY Rinnai Water Heaters 1 RIK-KIT (Optional) 1 (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.
Installation de la fourniture de gaz Se connecter chauffe-eau à l'approvisionnement en eau Les connexions de l'eau pour le chauffe-eau devraient suivre tous état et codes de plomberie local. S'il s'agit d'une installation standard, consultez le diagramme de tuyauterie pour Installation de base. 1. Sonder l'approvisionnement en eau pour le chauffe-eau sur la connexion de MNPT 3/4 "au bas de l'unité marqué « Prise d'eau », qui est l'approvisionnement en eau froide. 2.
Tout composé utilisé sur la jonction filetée du tuyau de gaz doit être d'un type qui résiste à l'action du gaz propane ou naturel. La conduite d'alimentation en gaz doit être étanche au gaz, du bon calibre et installée d'une façon permettant de fournir assez de gaz pour satisfaire la demande maximale du chauffe-eau et de tous les autres appareils fonctionnant au gaz du lieu sans qu'il y ait de chute de pression.
Reliez l'électricité Ajustez à l'haute altitude AVERTISSEMENT N'utilisent pas une rallonge ou un adaptateur brancher avec cet appareil. Le chauffage de l'eau doit être électriquement fondée conformément aux ordonnances et codes locaux ou, en l'absence de codes locaux, en conformité avec le Code électrique de la Nation, ANSI/NFPA 70 ou le Code électrique canadien, CSA C22.1.
Installation de le contrôleur de température Montage du contrôleur 1. Faire trois trous dans le mur, comme le montre. AVERTISSEMENT Désactiver le pouvoir. Ne pas tenter de connecter les contrôleurs de température avec le pouvoir. Bien que le contrôleur est un dispositif de basse tension, il y a 120 volts potentiels à côté les connexions de contrôleur de température à l'intérieur de l'unité.
Liste de vérification finale □ Vérifiez les conduites de gaz et les connexions des Le chauffage de l'eau n'est pas corrosifs composés fuites. dans l'air. □ Confirmer que la pression du gaz inlet est dans les □ L'approvisionnement en eau ne contient pas de limites. produits chimiques ou dépasse la dureté totale qui □ Confirmer que le chauffe-eau est coté pour le type nuira à l'échangeur de chaleur. de gaz fourni.
Diagramme en escalier PHASE NEUTRE 2837/2737 MODÈLE RIS 2 SEULEMENT RELAIS RIS 3 FUSIBLE 10A CONTACT DE DÉTECTION DE GEL ANTI-FOUDRE RELAIS 2 ANTI-FOUDRE VARISTOR RIS RELAIS 1 ALLUMAGE VARISTOR TERRE ALIMENTATION D'ÉNERGIE DE COMMUTATION 170V CC 12.
POUR LES APPLICATIONS INTÉRIEURES SEULEMENT V94i ...................... REU-VC2837FFU-US V94Xi .................... REU-VC2737FFU-US V75i ...................... REU-VC2528FFU-US V65i ...................... REU-VC2025FFU-US Chauffe-eau d’intérieur sans réservoir à ventilation directe Instructions d'utilisation POUR LES APPLICATIONS EXTÉRIEUR SEULEMENT V94e ..................... REU-VC2837W-US V75e ..................... REU-VC2528W-US V65e .....................
Directives d'opérations du consommateur pour le fonctionnement sécuritaire de votre chauffe-eau À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ Si vous ne suivez pas exactement ces instructions, il peut en résulter un départ d'incendie ou une explosion, causant dégâts matériels, blessures corporelles ou même mort. AVERTISSEMENT A. B. Si vous ne pouvez rejoindre le fournisseur, appelez le Cet appareil ne comporte pas de veilleuse.
Comment utiliser le contrôleur de température Le contrôleur MC-91-2 est le contrôleur de température standard qui et livré avec le chauffe-eau. Sur les modèles d’intérieur il est intégré dans son panneau frontal. Le contrôleur MCC-91-2 est pour des applications commerciales et à eau chaude nécessitant des températures plus élevées. Quand le contrôleur MCC-912 est connecté, ces températures plus élevées sont disponibles sur tous modèles de contrôleurs sur le système.
Comment définir la température Cette chauffe eau nécessite un débit minimum à exploiter. Ce taux se trouvent sur la page de spécification dans ce manuel. Dans certains cas lorsque vous n'obtenez pas l'eau chaude ou si l'eau alterne entre le chaud et le froid, c'est en raison du débit de l'eau étant ci-dessous ou à proximité du débit minimum. Accroître le débit devrait résoudre ces problèmes dans ces cas.
Plages de température avec un contrôleur de température Le chauffe-eau peut fournir l'eau à un seul réglage de la température à la fois. Les températures disponibles sont fournis ci-dessous. Une température inférieure à 98° F (37 ° C) peut être obtenue dans l'eau du robinet en mélange à l'eau froide. Pour modifier l'échelle de température de Celsius à Fahrenheit ou vice versa, appuyez et tenir le bouton « On/Off » pendant 5 secondes, tandis que le chauffe-eau est désactivée.
Entretien requis L'appareil doit être inspecté chaque année par un technicien qualifié. Réparations et entretien doivent être effectuées par un technicien qualifié. Le technicien de service doit vérifier le bon fonctionnement après entretien. AVERTISSEMENT Pour vous protéger contre les préjudices, avant d'effectuer la maintenance : Coupez l'alimentation électrique en débranchant le cordon d'alimentation ou en désactivant l'électricité au disjoncteur.
chaude. Mettre un seau sous le filtre au bas du chauffeeau à attraper toute l'eau qui est contenue à l'intérieur de l'unité. Dévissez le filtre à eau. Rincer le filtre à supprimer tous les débris. Installez le filtre et ouvrir les vannes d'isolement. Valve de decompression Exploiter la valve manuellement une fois par an. Ce faisant, il sera nécessaire de prendre des précautions AVERTISSEMENT installées pour vider automatiquement le chauffeeau en cas de coupure d’alimentation secteur.
Flushing l'échangeur de chaleur Un « LC » ou « 00 » code de diagnostic indique l'unité commence à chaux et doit être vidangée. Échec de vider l'appliance va causer des dommages à l'échangeur de chaleur. Dommages causés par l'accumulation de chaux ne sont pas couvert par la garantie de l'unité. KEY 1. Déconnectez l'électricité pour le chauffage de l'eau. 2. Fermer les robinets d'arrêt sur l'eau chaude et les conduites d'eau froides (V3 et V4). 3.
Drainage Manuel du chauffe-eau AVERTISSEMENT Pour éviter de burns, attendre jusqu'à ce que l'équipement se refroidit avant le drainage de l'eau. L'eau de l'appliance restera chaud après qu'il est éteint. Si le chauffe-eau ne va être utilisée pendant une période de temps au gel possible, il est recommandé que l'eau à l'intérieur du chauffe-eau être drainé. Manuellement drainer l'eau : 1. Couper l'approvisionnement en eau froide et d'approvisionnement en gaz. 2. Désactiver le contrôleur de température. 3.
Garantie du consommateur Garantie limitée Qu'est-ce qui est couvert ? La garantie limitée standard de Rinnai couvre tous les défauts dus aux matériaux ou à la main-d’œuvre quand le produit est installé et exploité en conformité avec les instructions d’installation écrites de Rinnai, en fonction des termes de ce document de garantie limitée. Cette garantie limitée se applique uniquement aux produits qui sont installés correctement dans les États-Unis et au Canada.
Comment obtenir le service au titre de la garantie ? Vous devez communiquer avec un fournisseur de service autorisé ou professionnels qualifiés et agréés État pour la réparation d'un produit en vertu de cette Garantie limitée. Pour trouver les coordonnées d'un tel fournisseur local, veuillez contacter votre point d'achat, ou allez sur le site Web de Rinnai (www.rinnai.us). Vous pouvez aussi téléphoner au 1-888835-9320 ou écrire à: 103 International Drive, Peachtree City, Georgia 30269, USA.
Value Series Manual 77
Value Series Manual
Value Series Manual 79
A tradition of true reliability. For nearly 100 years, we at Rinnai have been fiercely committed to delivering nothing less than a superior experience at every touch point. Beyond manufacturing the highest quality products, our people stand behind all that we make—before, during and long after installation.