Installation Instructions

TERMINAL WIRING
STEP 6
Wire cable to the terminal block at the top of the PCB as follows:
12 VDC: Power supply input.
ALARM: Normaly closed output.
TAMPER: Normaly closed dry output.
LEDS: IN - Enables all LEDs
OUT - Disables all LEDs
PULSE: IN - NO Pulse Count (1 pulse)
OUT -Alternative Polarity Pulse Count (2 pulses)
The COSMOS DT has two jumpers that can be either IN (used) or
OUT (unused).
Unused jumpers should be placed on one leg only to prevent their loss.
JUMPER SETTING
STEP 7
WALK TEST
STEP 8
Two minutes after applying power (a warm-up period), walk test the detector
over the entire protected area to verify proper operation of the unit.
The RK-225 needs a longer warm-up period of FOUR minutes. It enables a
powerful long range sensing capability and has increased sensitivity.
TOP VIEW SIDE VIEW
WIDE ANGLE (RL-115)
RK-210/215
CORRIDOR (RL-15)
RK-210/215
WIDE ANGLE
RK-225 RL-125
LONG RANGE
RK-225 (RL-17)
110
1.3m
/2m
83
3m
2.5m
(8'2")
0.4m
(1'4")
4m
(13'1")
23m
(75'5")
1.1m
(3'3")
2m
(6'7")
0.4m
(1'4")
3m
(9'10")
25m
(82')
1.1m
(3'3")
2.5m
(8'2")
0.4m
(1'4")
2.5m
(8'2")
10m/15m
(33/49')
1.1m
(3'3")
2.5m
(8'2")
0.4m
(1'4")
2m
(6'7")
5m
(16'5")
10m/15m
(33/49')
FINAL SETUP
STEP 9
After completing the installation and testing stages, ensure all jumpers
are at their desired positions. The unit is now ready for normal use.
The pigmented lens is attached to the inside of the front plastic cover using
a sensor protective sleeve.
1. Remove the sensor protecting sleeve by pushing up the clip that holds
the top part of the sleeve to the front cover.
2. Disconnect the lens from the sleeve by gently lifting it from the holding
pins that secure it to the sides of the sleeve.
3. Select the desired lens and make sure that the cut corners are pointed
upwards. (Fig. 4).
4. Place the two pins, located on the top and bottom part of the lens, into
the matching holes on the sleeve.
5. Place the holes on either side of the lens into their matching holding pins
on the sides of the sleeve.
6. Insert the protective sleeve back into place on the front cover.
ROKONET LIMITED WARRANTY
Rokonet Electronics, Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials
and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect
the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller can
not guarantee the performance of the security system which uses this product. Sellers obligation and liability under this
warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery,
any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty
of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental
damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever.
Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for
direct, indirect, or consequential damages or delay.
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona;
injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning
or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary,
robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal
injury or property loss as a result.
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product
fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from
under this limited warranty or otherwise, regardless of cause or origin, sellers maximum liability shall not exceed the purchase
price of the product, which shall be complete and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.
ROKONET ELECTRONICS LTD.
14 HACHOMA ST.
75655 RISHON LETZION. ISRAEL.
TEL: (972) 3 961 6555 FAX: (972) 3 961 6584
7in71fmb
© 2001 Rokonet Electronics Ltd
05/01
TEL: 1 914
TEL: 44 (0)
TEL: 33 (0)
TEL: 39 (02)
TEL: 55 (21)
FAX: 1 914
FAX: 44 (0)
FAX: 33 (0)
FAX: 39 (02)
FAX: 55 (21)
ROKONET USA:
ROKONET UK:
ROKONET FRANCE:
ROKONET ITALY:
ROKONET BRAZIL:
592 1068
1527 576 765
155 123390
3925 354
496.3544
592 1271
1527 576 816
148 863042
3925 131
496.3547
Fig 2: Jumper positions.
PROCEDURE FOR CHANGING LENSES
Fig 4.
Lens Change
Procedure
SPECIFICATIONS
ELECTRICAL
Current consumption: 19mA at 12 VDC
45mA at 16 VDC
(MAX with all LED's ON)
Voltage requirements: 9-16 VDC regulated
Alarm contacts: 24 VDC, 50 mA
Tamper contacts: 24 VDC, 0.1A
OPTICAL
Filtering: White Light Protection
PHYSICAL
Size: 127.6 x 64.2 x 40.9mm
(5 x 2.5 x 1.6 in.)
ENVIRONMENTAL
Operating temperature: -10ºC to 55ºC (14ºF to 131ºF)
Storage Temperature: -20ºC to 60ºC (-4ºF to 140ºF)
1. The models have been listed by Underwriters
Laboratories for use with the wide angle lens
only .
2. The detector is intended to be connected to
a listed burglar alarm control unit capable
of providing 4 hours of standby power.
Specifications are subject to change without prior notice.
Should any questions arise, contact your distributor.
NOTES FOR UL
COSMOS
DT SERIES
RK-210,215,225
INSTALLATION
INSTRUCTIONS
Fig 3: Cosmos DT Lenses
4
IN
OUT
NOTE
Make sure to replace front cover before Walk Test.
The MW range can be adjusted using the potentiometer located at the
bottom of the PCB. It is important to set the potentiometer to the lowest
possible setting that will still provide coverage for the entire
protected area.
5 6
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment on and off, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and the receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible for
compliance (Rokonet Electronics Ltd.) could void the user's authority to operate the equipment.
NOTE