Install guide 8030C MENU M PROGRA T RESE MENU PROGRAM CTOR -T FA T RESE Y RATE DISPLA CALIB Customer Support: 888-515-2585 or Visit our website www.ritetemp-thermostats.
Install guide 8030C Caution To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the circuit breaker, or at the appliance. Tools You will need #1 Phillips screwdriver (small) and Drill with 3/16-in. (4.8mm) bit for this installation. 1 Location PG 1 On replacement installations, mount the new thermostat in place of the old one if possible.
2 Remove old unit Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side or front. These must be loosened. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identification. Caution Read instructions carefully before removing any wiring from existing thermostat. Wires must be labeled before they are removed.
Before you Connect Wires Please follow these guidelines for safe and secure wire connections. Strip insulation 3/8 in. (9.5mm) from wire ends. Take care not to damage the labels for each wire in handling. Connect labeled wires only to a terminal with corresponding letter. Bend the wire slightly, insert the wire under the contact plate and tighten the screw down onto the wire. Do not allow wires to touch each other or parts on thermostat.
When you have finished making connections. hook the top of the body onto the base, swing the body down, and snap the body onto the base. MENU M PROGRA ET RES 5 Install Batteries The 8030C requires batteries to operate your furnace and retain its programming in memory. Switch MODE switch to OFF and the FAN switch to AUTO. Remove the unit from the wall turn it AA AA over and install 2 AA alkaline batteries according to the polarity noted in the compartment.
Check Unit cont. Note: If you have an electric furnace system and the blower does not operate after installation, remove the thermostat, turn it over, and find the electric/gas heat selector jumper on the back of the control unit. Switch the Gas/Elect. jumper to Elect. to "Elect"(see Diag below). Move the selector jumper to the ELEC position. Congratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the new thermostat.
ce From Furna C R or RH W STEP 1 - Connect the R (or RH) wire to the RH terminal on the thermostat. This connects the Heater Power to the thermostat. 2 WIRE Heating (GAS MILLIVOLT or 24vac Thermostat A jumper wire C STEP 2 - Connect the W wire to the W terminal on the thermostat. This connects the heater control line to the thermostat. R W HEAT Power HEAT FURNACE Your Heater is now connected to the thermostat. Return To Page 7 NOTE: Wires marked with the dotted line are optional.
ace From Furn it and AC un Y RH or R G C W 4 WIRE STEP 1 - Connect the Y wire to the Y terminal on the thermostat. This connects to the Cooler compressor. STEP 2 - Connect the RH or R wire to the RH terminal on the thermostat. This connects the Heater/Cooler Power. Thermostat A jumper wire C RH Heat Power W Y G Heat Cool Comp FAN HVAC SYSTEM STEP 3 - Connect the W wire to the W terminal on the thermostat. This connects to the heater control line.
SINGLE STAGE STEP 1 - Connect the G HEAT PUMP wire to the G terminal on jumper wire Thermostat the thermostat. Y O A This connects the Fan. or B STEP 2 - Add a jumper jumper O or B wire between W and Y. wire R C STEP 3 - Connect the Y wire to G O or B Y R C the Y terminal on the thermostat. 24VAC Change This connects the Compressor. Comp FAN Power Over STEP 4 - Connect the O or B wire to the O Single Stage HEAT PUMP or B terminal on the thermostat.