Instructions / Assembly

READ & SAVE
INSTALLATION & OPERATION INSTRUCTIONS
We recommend professional electrician to install this lamp
The manufacturer will not accept liability for injury or damage resulting from incorrect use of the lamp and
luminaire.
TOOLS & MATERIALS REQUIRED
Adjustable wrench
Flat Blade screw driver
Step Ladder
Wire cutters
Wiring supplies as required by electrical code
CAUTION: Before assembling your Lighting fixture,
refer to the section titled ELECTRICAL
CONNECTIONS. If you feel you do not have
electrical wiring experience, refer to a do-it yourself
wiring handbook or have your fixture installed by a
qualified licensed electrician.
GENERAL
1. To ensure the success of the installation, be sure to
read these instructions and review the diagrams
before beginning.
2. All electrical connections must be in accordance
with local codes, ordinances, or the National
Electrical Code. If you are unfamiliar with methods
of installing electrical wiring, secure the services of a
qualified licensed electrician.
3. These fixtures are intended to be mounted to a 4” x
4” x 2-1/8” deep metal octagon outlet box. The box
must be directly supported by the building structure.
5. Before starting the installation, disconnect the
power by turning off the circuit breaker of by
removing the fuse at the fuse box. Turning the power
off using the light switch is not sufficient to prevent
electrical shock.
UNPACK THE FIXTURE
Check the contents of the box. You should receive:
Mounting hardware package
Fixture assembly(s)
PREPARE THE FIXTURE
NOTE: FIRST TURN OFF ELECTRICITY
Refer to figure 1 for illustration of fixture parts and
assembly.
1. If you are replacing an existing fixture, disconnect
and remove the old fixture. Expose the supply wiring
from the outlet box.
2. Fasten the mounting bracket to the outlet box using
the two screws supplied.
3. Screw the threaded pipe into the bottom of lamp
holder base.
4. Attach the shade onto the threaded pipe and secure
with finial.
5. Screw the canopy onto the top end of tube.
Make electrical connections - SEE BELOW.
ELECTRICAL CONNECTIONS
Required Supply Circuit: 120V, 60 Hz
First proceed by identifying the wires on your
luminary: The POSITIVE wire can be identified by
its SMOOTH outer coating (NOT RIBBED), and the
NEGATIVE wire can be identified by its RIBBED
outer coating (RIBBED).
Connect the luminary (SMOOTH) POSITIVE wire
to the BLACK (line) wire of the supply circuit.
Next, connect the (RIBBED) NEGATIVE wire of
your luminary to the WHITE (neutral) wire of the
supply circuit. Connect the green (or bare copper)
colored wire from the supply circuit to the GREEN
GROUND SCREW located on the MOUNTING
BRACKET (see figure).
Use UL/CSA Listed wire connectors (included)
suitable for the size, type and number of
conductors. No loose strands or loose connections
should be present. Secure wire connectors with
UL/CSA Listed electrical tape.
FINAL ASSEMBLY
1. Raise the fixture to the ceiling, attach the canopy to
the mounting bracket, pass the two machine screws
through the holes on canopy and secure with the
screw nut.
2. Install bulbs (not provided).
CAUTION: Refer to the wattage caution label
located near the lamp holder for the recommended
maximum wattage - do not exceed recommended
wattage.
Restore electricity and check the operation of your
lighting fixture.
MADE IN CHINA

Summary of content (2 pages)