Instructions / Assembly

MODEL NO.: 20060
4
3. Tools Required
Step ladder
Pliers
Screwdriver (flat head and phillips)
Electrical tape
Circuit tester
4. Installation Preparation
To prevent personal injury and damage, ensure
that
the hanging location allows the blade a
clearance of 7ft (2.13m) from the floor and 30 in
(76cm) from any wall or obstruction.
The fan is suitable for room sizes up to 400 square
feet (37.2 square meters).
This fan can be mounted with a down rod
on a normal or vaulted ceiling. Down rod is
included, 6” length.
This fan can also be mounted using flush mount
installation as seen in diagram.
5. Hanging Bracket Installation
Turn off circuit breakers to current fixture from breaker panel
and be sure operating light switch is turned to the OFF
position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury and fire hazard.
Remove existing fixture
WARNING: When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and can
support the full weight of the fan. Ensure the outlet box is clearly
marked “Suitable for Fan Support". If not, it must be replaced
with an approved outlet box. Failure to do so can result in
serious injury.