2425H. The XR-2425H is powered by one injector port rated at 30W or higher. See the
Installation Guide for your PoE device for more information.
NOTE: Xirrus-supplied PoGE Injectors and switches must be installed and used
indoors.
2) Choose a Suitable Location
The XR-2425H is tested to IP65 water proof and dust proof requirements to protect against
severely wet and dusty environments. For optimal placement, we recommend that a predictive
survey be performed by a qualified Xirrus partner.
Choose a location that is not subjected to submersion.
Direct sunlight may raise the effective ambient temperature many degrees above air
temperature. It is best to choose a location that has some protection from the sun.
The maximum cable length between the XR-2425H and the RJ-45 Ethernet Network is 100
meters. The PoGE Injector is not a repeater, so its location will not increase this distance.
The XR-2425H can operate from a Wireless Distribution System (WDS) link. However, the
unit will need to be configured via the Ethernet connection prior to mounting and power
must still be supplied via the RJ-45 Ethernet connector.
Keep the unit away from electrical devices or appliances that generate RF noise—at least 3
to 6 feet (1 to 2 meters).
3) Prepare a Ground Source
Part of the mechanical installation is to ensure that the Array is grounded to earth ground to
dissipate any static electric charge that may develop due to wind.
Determine a good electrical earth ground point near the Array mounting location. If an
earth ground point is not available, consult an electrician to have one installed.
Before the Array is attached to a wall or pole, secure a grounding wire and lug to the Array
with the provided screw in the location indicated by the arrow, below.
Attach grounding
wire and lug here