Instructions / Assembly

GR2045401-RG-00/GR2045406-RG-00 20 of 27 20150831-Ver1
OPERATING INSTRUCTIONS
LIGHTING INSTRUCTIONS
BEFORE LIGHTING
WARNING
Inspect the gas supply hose prior to turning the gas “ON”.
If there is evidence of cuts, wear, or abrasion, it must be replaced prior to use.
Do not use the grill if the odor of gas is present.
Only the pressure regulator and hose assembly supplied with the unit should be
used.
Perform the “LEAK TEST” according to instructions before operating the grill.
ALWAYS keep your face and body as far away from the burner as possible while
lighting.
Electrode Check
With the assistance of another person, perform this Electrode Check before proceeding.
This test will ensure that the Spark Electrode Tips are properly positioned so your
grill lights easily and properly.
Be sure all Control Knobs are set to “OFF” and open the Grill Lids.
Have your assistant stand behind and to the left of the grill and look toward the front
of the grill box. Never put your face inside the Grill Head.
Press the Igniter Cap. You should hear a “clicking” sound. Your assistant should
see a blue spark from Electrode Tips to the burner port; if a spark is present
Electrode Tips are properly positioned.
If no spark is seen, the ignition probe needs to be adjusted by using a collar to
adjust the ignition probe so that it is pointing to the burner port.
Recheck the Electrode; if no “clicking” sound is heard, check if (1) LR-6 /AA Battery
is installed backwards, and (2) electric wires may be loose. Remove the Battery
and inspect the Igniter Junction Box found behind the Control Panel and reconnect
any loose wires.
GAS Collector
Spark Electrode Tips