Instruction Manual

18-0650-02 Revsion A
Page 9 of 13
Step
Action
2
Carefully
pull the optical Adapter forward. A pair of needle nose pliers may be helpful in grasping
the adapter. Note the orientation of the key slot (up) and spring clip (back).
3
After p
ulling the adapter clear of the instrument, gently
remove the internal male connector from the
adapter,
being careful not to touch or bump the end/tip of the connector. Set the fiber
assembly/connector to the side where it will not be damaged.
4
Clean the internal male Connector tip with a soft alcohol saturated swab; use clean air to gently dry
the tip.
5
Install a new SC adapter on the internal male connector
and gently slide back into the enclosure.
Verify the adapter and connector are in the
same orientation as shown above.
6
Reinstall the black SC slider with long screws.
(p) p
g