User`s guide

32
User's Guide ADI-192 DD © RME
10.4 Sample Rate Converter
Self adjusting, high order aliasing filter (-144 dB)
Resolution: 24 bit
Dynamic Range: 140 dB RMS unweighted, 143 dBA
Distortion (THD+N): -140 dB
I/O ratio > 1:7 / 7:1
Input / Output sample rate range: 28 kHz - 204 kHz
Supports varispeed operation through fast tracking
Group delay: 141 samples (3.2 ms @ 44.1 kHz)
10.5 General
Power supply: Internal switching PSU, 100 - 240 V AC, 20 Watt
Typical power consumption: 6 Watt
Dimensions including rack ears (WxHxD): 483 x 44 x 242 mm (19" x 1.73" x 9.5")
Dimensions without rack ears/handles (WxHxD): 436 x 44 x 235 mm (17.2" x 1.73" x 9.3")
Weight: 2 kg ( 4.4 lbs)
Temperature range: +5° up to +50° Celsius (41° F up to 122°F)
Relative humidity: < 75%, non condensing
10.6 Connector Pinouts
D-Sub TDIF-1
The 25 pin D-sub connectors are wired according to TDIF-1, version 1.1:
Signal Out
1/2
Out
3/4
Out
5/6
Out
7/8
Out
LRCK
Out
EMPH
Out
FS0
Out
FS1
D-sub 1 2 3 4 5 18 6 19
Signal In
FS1
In
FS0
In
EMPH
In
LRCK
In
7/8
In
5/6
In
3/4
In
1/2
D-sub 20 8 21 9 10 11 12 13
GND is connected to pins 7, 14, 15, 16, 17, 22, 23, 24, 25.
AES/EBU
The XLR connectors are wired according to AES3-1992:
1 = GND (shield)
2 = Signal
3 = Signal
AES/EBU and SPDIF are biphase modulated signals, therefore polarity doesn't matter. Pins 2
and 3 are neither hot nor cold, they carry the same signal. But as AES3 uses a balanced trans-
mission they are inverted in polarity.