Specifications
3-8
5. Transceiver Voice Enable
When this channel is enabled and the remote base is enabled, voice messages will be
transmitted by the transceiver. When this channel is off, PTT #2 will not activate
unless repeater COR #1 is active.
6. Transceiver Auto Disconnect Enable
When this channel is enabled, the link will disconnect automatically after a period of
repeater inactivity. Voice message #16 will be called to announce the transceiver has
disconnected. A link or repeater COR input will keep the Transceiver activate until
the repeater returns to rest. A rest period of up to 29 minutes can be selected with
the [*619*] programming command. When the CAT-1000B is initialized this timer
defaults to 600 seconds.
7. Computer Interface Enable
When this channel is enabled, bi-directional communications can be established through
the RS-232 and TTL ports to control and program a remote base transceiver with a
computer interface.
8. Ring Detector Enable
During control operator call-in, upon receipt of a ring detector input, the CAT-1000B
will simulate an off-hook condition. The delay in answering the phone is user
programmable with the [*617*] programming command. When the CAT-1000B is initialized,
the ring detector timer defaults to 2 seconds. When this channel is turned off, the
controller will not answer the phone. This feature is useful when more than one
telephone device is sharing the same line.
Zone 7 Hardware Inputs
1. Input #1 Enable
When this channel is enabled the CAT-1000B in response to a positive voltage input on
connector J1-1 by executing the command stored in the Input #1 memory buffer.
2. Input #2 Enable
When this channel is enabled, a positive voltage on J1-10 will execute the command
stored at the Input #2 memory buffer.
3. Input #3 Enable
When this channel is enabled, a positive voltage on J1-11 will execute the command
stored at the Input #3 memory buffer.
4. Input #4 Enable
When this channel is enabled, a positive voltage on J1-12 will execute the command
stored at the Input #4 memory buffer.
5. Input #5 Enable
When this channel is enabled, a positive voltage on J1-13 will execute the command
stored at the Input #5 memory buffer.
6. Input #6 Enable
When this channel is enabled, a positive voltage on J1-23 will execute the command
stored at the Input #6 memory buffer.
7. Input #7 Enable
When this channel is enabled, a positive voltage on J1-24 will execute the command
stored at the Input #7 memory buffer.
8. Input #8 Enable
When this channel is enabled, a positive voltage on J1-25 will execute the command
stored at the Input #8 memory buffer.