Specifications
3-9
Zone 8 User Function Outputs
1. Output #1 Enable
When this channel is enabled, user function switch #1 is turned on. Connector J1 pin
5 will switch 28VDC and sink 150 MA. This feature provides remote control of other
equipment at the repeater site.
2. Output #2 Enable
When this channel is enabled, user function switch #2 is turned on. Connector J1 pin
6 will switch 28 VDC and sink 150 MA.
3. Output #3 Enable
When this channel is enabled, user function switch #3 is turned on. Connector J1 pin
7 will switch 28 VDC and sink 150 MA.
4. Output #4 Enable
When this channel is enabled, user function switch #4 is turned on. Connector J1 pin
8 will switch 28 VDC and sink 150 MA.
5. Output #5 Enable
When this channel is enabled, user function switch #5 is turned on. Connector J1 pin
9 will switch 28 VDC and sink 150 MA.
6. Output #6 Enable
When this channel is enabled, user function switch #6 is turned on. Connector J1 pin
18 will switch 28 VDC and sink 150 MA.
7. Output #7 Enable
When this channel is enabled, user function switch #7 is turned on. Connector J1 pin
19 will switch 28 VDC and sink 150 MA.
8. Output #8 Enable
When this channel is enabled, user function switch #8 is turned on. Connector J1 pin
20 will switch 28 VDC and sink 150 MA. To prevent damage to the NE5090, do not exceed
one-watt total power dissipation.
Remote Activation Of The RS-232 Port
To activate the RS-232 port, key-up and enter the control operator prefix code
followed by [97]. Un-key and the CAT-1000B will automatically switch to the computer
terminal programming mode. This RS-232 port is configured for a baud rate of 4800. A
special cable must be fabricated, see Figures 7-2.
Read Software Version
To read the current software version of the Program and Voice ROMs, key-up and enter
the control operator prefix code followed by [98]. Un-key and the voice will read the
software versions.
Control By Telephone
In the control operator mode the CAT-1000B will accept commands to read and load
memory files by telephone. To read the current memory file enter [90#]. To load a
memory file enter:
COMMAND DESCRIPTION COMMAND DESCRIPTION
91# Load memory file 1 95# Load memory file 5
92# Load memory file 2 96# Load memory file 6
93# Load memory file 3 97# Load memory file 7
94# Load memory file 4 98# Load memory file 8