Specifications

4-3
Monitor Repeater By Telephone
This feature permits a control operator to monitor repeater activity through the
telephone. Call the repeater, when the CAT-1000B answers, a beep will be heard.
Enter the monitor repeater prefix [850] followed by a [#]. Any signal received by the
repeater will be heard on the phone. To make a call or join a conversation in
progress, enter [1#]. The repeater will remain in the transmit mode with an audio
path to the transmitter. To return to monitor only, enter [4#]. To terminate
monitoring by phone, enter [0#]. This mode will disconnect when the [*615*]
programming timer, times-out. A series of time-out warning beeps will be sent. You
have 30 seconds to reset the timer by entering [9#]. To test for intermod or
desensitivity, enter [3#] to turn the transmitter OFF and [2#] to turn the transmitter
ON. If an autopatch is attempted while in the monitor mode, the voice will say:
"TELEPHONE LINE IN SERVICE". Note: Zone 5 channel 2 must be enabled.
ENTER CONTROL COMMANDS
0# Hang-up (Terminate Monitor Mode)
1# Force Entry (Talk on Repeater)
2# Turn ON Repeater Transmitter
3# Turn OFF Repeater Transmitter
4# Return to monitor only mode
9# Extend Timer
Telephone Line Busy
If the repeater shares a phone line and a positive voltage is applied to the Busy #1
input J4-2, the voice will say: "TELEPHONE LINE IN SERVICE" and the autopatch will be
rejected. You must supply the telephone line monitoring circuit that will provide a
positive DC voltage to the CAT-1000B when the telephone is off hook.
Transceiver Control By Repeater Input
This feature permits repeater users to control a transceiver connected to the second
RF port of the CAT-1000B with a simple DTMF entry.
Transceiver Disconnect
Key-up on the repeater's input and enter the transceiver control prefix [500],
followed by a 0. The CAT-1000B will separate the repeater and transceiver and enable
the repeater's time-out timer. The voice will announce the Transceiver disconnect
message stored at voice message table position 09. The transceiver disconnect
announcement can be changed with the [*3109] programming command. Example: With a
transceiver control prefix of 500, turn OFF the transceiver.
Key-up and enter: 5 0 0 0
└─┼─┘ └─────── Command (OFF)
└─────────── Transceiver Control Number
Transceiver Connect
Key-up on the repeater's input and enter the transceiver control prefix [500],
followed by a 1. The CAT-1000B will connect the repeater and transceiver and disable
the repeater's time-out timer. The voice will announce the transceiver connect
message stored at voice message table position 10. The transceiver connect
announcement can be changed with the [*3110] programming command. Example: With a
transceiver control number of 500, turn ON the transceiver.
Key-up and enter: 5 0 0 1
└─┼─┘ └─────── Command (ON)
└─────────── Transceiver Control Number