5-9
Erase Remote Base Frequency Locations (01-40)
Key-up and send [*42XX]. Un-key and the voice will say: "CONTROL OK."
Expanded User Function Switches
The DR-1000 Digital Voice Recorder board makes available an additional eight switches
to control a CTCSS encoder-decoder or any other equipment at the repeater site. The
switch settings are stored as a group in a forty-position table. These switches can
be changed by a DTMF command or automatically by the action of the scheduler.
Read DR-1000 Switch Locations (01-40)
Key-up and send [*46XX]. Un-key and the voice will announce the settings of each
switch stored at memory location [XX]. If all switches are OFF, the voice will say:
"ALL CLEAR". If some switches are ON the voice will read back those switches in
order.
Program DR-1000 Switch Locations (01-40)
Key-up and send [*47XX] followed by the settings of the eight switches. Un-key and
the voice synthesizer will say: "CONTROL OK". Example: On the DR-1000 at table
position 5, set switches 1,3,5 and 6 to ON.
*4705 1 0 1 0 1 1 0 0
Programming └─Switch #8
Command ─────┘ └───Switch #7
Switch #1────────┘ └─────Switch #6
Switch #2──────────┘ └───────Switch #5
Switch #3────────────┘ └─────────Switch #4
Erase DR-1000 Switch Locations (1-40)
Key-up and send [*48XX]. Un-key and the voice will say: "CONTROL OK".
Control - Prefix Number Memory
This memory area is reserved for storage of control and prefix numbers. These numbers
can be from one to seven digits and will change to a default value when the CAT-1000B
is powered up with dip-switch #7 set to the ON position. See the Control Number Table
for default values.
Control Operator Prefix Number [*501*]
This number must precede the command used to change the settings of REPEATER #1
control channels in Zones 1 through 8. Example: To program a Control Operator Prefix
Number of 100, key-up and send [*501*100], Un-key and the voice will say: "CONTROL
OK." Access to this number should be limited to control operators.
Link Bridge Number [*502*]
When the second RF port is configured for link operation, this number must be entered
to have the CAT-1000B accept control, programming and user commands via the link
receiver. Example: To program a Link Bridge Number of 150, key-up and send
[*502*150], un-key and the voice will say: "CONTROL OK."
Memory Recall Prefix [*503*]
This number must precede the command used to execute a memory move from storage into
active memory. Example: To program a Memory Recall Prefix Number of 175, key-up and
send [*503*175], Un-key and the voice will say: "CONTROL OK."
DTMF Generator Prefix [*504*]
This number must precede the DTMF Generator table position number. When entered by a
repeater user the CAT-1000B will generate the DTMF command stored at that table
position. Example: To program a DTMF Generator Prefix Number of 300, key-up and send
[*504*300], Un-key and the voice will say: "CONTROL OK."