Specifications

5-19
Program Paging Tone Locations (01-20)
Key-up and send [*98XX] followed by the paging tone group and tone number. Un-key and
the voice will say: "CONTROL OK." Example: Program [707 - 1395Hz] tones at table
position 2.
Program Command ──┐ ┌────────First Tone Group
│┌───────First Tone Number
*98 02 24 68
Paging Tone │└────Second Tone Number
Table Position──────┘ └─────Second Tone Group
TWO-TONE SEQUENTIAL PAGING FREQUENCIES
Tone Group 1 Group 2 Group 3 Group 4 Group 5 Group 6
1 349.0 600.9 288.5 339.6 584.8 1153.4
2 368.5 634.5 296.5 358.6 617.4 1185.2
3 389.0 669.9 304.7 378.6 651.9 1217.8
4 410.8 707.3 313.0 399.8 688.3 1251.4
5 433.7 746.8 953.7 422.1 726.8 1285.8
6 457.9 788.5 979.9 445.7 767.4 1321.2
7 483.5 832.5 006.9 470.5 810.2 1357.6
8 510.5 879.0 1034.7 496.8 855.5 1395.0
9 539.0 928.1 063.2 524.6 903.2 1433.4
0 330.5 569.1 1092.4 321.7 553.9 1122.5
Erase Paging Tone Locations (01-20)
Key-up and send [*99XX]. Un-key and the voice will say: "POSITION XX IS CLEAR."
Pulse Dialing
The CAT-1000B will dial in DTMF or PULSE. If Zone 5 Channel 1 is enabled, the
controller will be in the pulse dialing mode. Use the [*298] and [*299] programming
commands to select between the 10 and 20 pulse per second rate.
Read Pulse Dialing Rate
Key-up and enter [*298], un-key and the voice will say: "TELEPHONE SET FOR TEN PPS" or
"TELEPHONE SET FOR TWENTY PPS".
Program Pulse Dialing Rate
To change the pulse dialing rate setting, key-up and enter [*299]. Use this command
to toggle between the ten and twenty pulse per second rates. The voice will announce
the rate each time it is toggled.
Exit Programming Mode [*0]
To exit the programming mode and return to normal repeater operation, key-up and send
[*0]. Un-key and the voice will say: "MANUAL EXIT." If you fail to exit the
programming mode, when the programming timer [*615*] expires, the CAT-1000B will
automatically return to normal repeater operation. The voice will say: "TIMER EXIT."