Specifications
8-3
CTCSS Control
50 Encoder OFF 51 Encoder ON 52 Decoder OFF 53 Decoder ON
Read Remote Base RF Power
To check the setting of the Remote Base RF power, key-up and enter the Remote Base
Frequency Load prefix, followed by [6].
Set Remote Base RF Power
To set the RF power, key-up and enter the Remote Base Frequency Load prefix, followed
by the two-digit number that represents the desired power setting from Figure 8-5.
Example: With a prefix of 525, set RF power to high. The voice will say: "RF-POWER-
HIGH."
Key-up and enter: 5 2 5 6 3
Load Prefix ────┴─┴─┘ └─┴─────── RF Power Level 3 (High)
Remote Base RF Power Control
61 Level 1 (Low) 62 Level 2 (Medium) 63 Level 3 (High)
Read Remote Base DC Power
To check the setting of the Remote Base DC power, key-up and enter the Remote Base
Load prefix, followed by [8].
Set Remote Base DC Power
To set the remote base DC power, key-up and enter the Remote Base Frequency Load
prefix, followed by the two digit number that represents the DC power command.
Example: With a prefix of 525, turn off the DC power. The voice will say: "DC POWER
OFF."
Key-up and enter: 5 2 5 8 0
Load Prefix ───┴─┴─┘ └─┴─────── DC Power Off
Remote Base DC Power Control
80 DC Power OFF 81 DC Power ON
Reset the RBI-1 Interface
To reset the RBI-1 by remote control, (push the reset switch on the back of the RBI-
1), key-up and enter the Remote Base Frequency Load prefix, followed by the [#].
Key-up and enter: 5 2 5 #
└─┼─┘ │
Load Prefix ────┘ └──────── Reset Command