Track length
The DR-1000 consists of sixteen tracks of fixed lengths. They are:
Track #1 30 seconds Track #9 10 Seconds
Track #2 30 seconds Track #10 10 Seconds
Track #3 30 seconds Track #11 6 Seconds
Track #4 30 seconds Track #12 6 Seconds
Track #5 15 seconds Track #13 6 Seconds
Track #6 15 seconds Track #14 6 Seconds
Track #7 10 seconds Track #15 6 Seconds
Track #8 10 seconds Track #16 6 Seconds
Record DVR Tracks By Radio (01-16)
The CAT-1000B must be in the programming mode to record DVR tracks. Key-up and enter
the seven digit unlock code. Once unlocked, key-up and send [*95XX]. Un-key and the
voice will say: "START MESSAGE". Key-up and enter the message to be stored at track
"XX". Un-key and the voice will say: "CONTROL OK". To review the message, key-up and
send [*94XX]. Un-key and the CAT-1000B will play the message stored at track "XX".
To erase a message, key-up and send [*96XX]. Un-key and the voice will say: "CONTROL
OK". Tracks can be recorded, played or erased in any order. Total record time is
four minutes. Maximum track length is thirty seconds. The DR-1000 cannot be used in
a mailbox type application. It can only be used for announcement type messages.
Record DVR Tracks By Telephone (01-16)
Call the repeater by telephone. The CAT-1000B will answer and send a beep. Enter the
seven digit unlock code followed by the [#]. Once unlocked, enter [*95XX#]. The
voice will say: "START MESSAGE" and the record function will start. Speak into the
phone to record the message. To stop the recording, press the [#]. Press and release
the [#] quickly. The DVR is programmed to automatically back-up and erase the [#]
tone from the end of the message. The voice will say: "CONTROL OK". To review the
message, enter [*94XX#]. Un-key and the CAT-1000B will play the message stored at
track "XX" over the telephone. The CAT-300 will play the message over the
transmitter. To erase a message, enter [*96XX#]. The voice will say: "CONTROL OK".
Audio Level Adjustment
Set the RECORD level control R2 and the PLAYBACK level control R3 to mid-range. This
set the audio path through the DVR at approximately unity gain. Use R2 and R3 to
adjust the audio levels as desired. Measure the TX1 audio level at TP5. Adjust R3 so
the playback audio at TP5 is the same level as the audio of the original signal.
Expanded User Function Switches
The eight expanded user function switches are open collector relay drivers. Each
driver can sink up to 80mA and switch 40 VDC. When connected to the CAT-1000B, use
the second expanded user function table, controlled by the [580] default prefix code.
Place diodes across the relay coils to protect the driver from negative spikes
produced when the relay coil collapses.