User`s guide
64 
User's Guide HDSPe MADI FX © RME 
25.8.3 OSC Page 
The OSC page has four independent settings for up to four MIDI remote controls via Open 
Sound Control (OSC). This is a network based remote protocol that can be used for example by 
Apple’s iPad with the app TouchOSC or Lemur to wirelessly remote control TotalMix FX running 
on a Mac or Windows computer. 
Index 
Select one of four settings pages and thus remote controls. Settings are remembered automati-
cally. To activate or deactivate any of the four remote controls check or uncheck ‘In Use’. 
TotalMix FX OSC Service 
¾  IP. Shows the network address of the 
computer running TotalMix FX (local 
host). This address must be entered 
on the remote side. 
¾  Host Name. Local computer name. 
¾  Port incoming. Must match the 
remote entry ‘Port outgoing’. Typical 
values are 7001 or 8000. 
¾  Port outgoing. Must match the remote 
entry ‘Port incoming’. Typical values 
are 9001 or 9000. 
Remote Control 
¾  IP or Host name. Enter the IP or host 
name of the remote control. Please 
note that the IP number usually works 
better than the host name. 
Options 
¾  Send Peak Level. Activates the 
transmission of the peak level meter 
data.  Peak Hold activates the peak 
hold function as set up for the TotalMix 
level meters in the preferences. 