16. Hotline – Troubleshooting 
The newest information can always be found on our website www.rme-audio.com, section FAQ, 
Latest Additions. 
The dialog 'New hardware component found’ does not appear: 
•  Check whether the PCI interface is correctly inserted in the PCI slot. 
The card and drivers have been installed correctly, but playback does not work: 
•  Check whether the Hammerfall DSP appears in the Device Manager. If the ' Hammerfall 
DSP’ device has a yellow exclamation mark, then there is an address or interrupt conflict. 
•  Even if there is no yellow exclamation mark, it is still worth checking the ‘Resources’ tab. 
The input signal cannot be monitored in real-time 
•  ASIO Direct Monitoring has not been enabled, and/or monitoring has been disabled globally 
(for example in TotalMix). 
Playback works, but record doesn’t 
•  Check that there is a valid signal at the input. If so, the current sample frequency is dis-
played in the Settings dialog. 
•  Check whether the HDSP system has been selected as recording device in the audio appli-
cation. 
•  Check whether the sample frequency set in the audio application (‘Recording properties’ or 
similar) matches the input signal. 
Crackle during record or playback 
•  Increase the number and size of buffers in the ‘Settings’ dialog or in the application. 
•  Try different cables (coaxial or optical) to rule out any defects here. 
•  Check that cables/devices have not been connected in a closed loop. If so, set the system’s 
clock mode to ‘Master’. 