User`s guide
User's Guide HDSPe MADI © RME
21
12.5 Digital Recording 
Unlike analog soundcards which 
produce empty wave files (or noise) 
when no input signal is present, digital 
interfaces always need a valid input 
signal to start recording. 
Taking this into account, RME added a 
comprehensive I/O signal status 
display to the HDSPe MADI, showing 
sample frequency, lock and sync status 
for every input. 
The sample frequency shown in the 
fields Clock Mode and MADI Input 
Status is useful as a quick display of 
the current configuration of the unit and 
the connected external equipment. If no 
sample frequency is recognized, it will 
read ‘No Lock’. 
This way, configuring any suitable 
audio application for digital recording is 
simple. After selecting the correct input, 
HDSPe MADI displays the current 
sample frequency. This parameter can 
then be changed in the application’s 
audio properties (or similar) dialog. 
It often makes sense to monitor the 
input signal or send it directly to the 
output. This can be done at zero 
latency using TotalMix (see chapter 25). 
An  automated control of real-time monitoring can be achieved by Steinberg’s ASIO protocol 
with RME’s ASIO drivers and all ASIO 2 compatible programs. When 'ASIO Direct Monitoring' 
has been switched on, the input signal is routed in real-time to the output whenever a recording 
is started (punch-in). 