88192 A/D D/A Converter User’s Guide
Safety 6408 216th Street SW | Mountlake Terrace, WA 98043 USA T +1.425.778.7728 F +1.425.778.7727 | www.SymetrixAudio.
Safety 88192 A/D D/A Converter What Ships in the Box • An 88192 hardware device. • A detachable power cord. • This User’s Guide. Getting Help If you have questions beyond the scope of this user’s guide, contact our Customer Support Group in the following ways: Tel: Important Safety Instructions ! @ # $ % +1.425.778.7728 8:00 am to 4:30 pm Monday through Friday, Pacific Time ^ & Web: http://www.SymetrixAudio.com This device complies with part 15 of the FCC Rules.
Introduction User’s Guide Introduction The Lucid 88192 A/D D/A Converter features eight channels of analog input and output at internal sampling rates of up to 192 kHz, while simultaneously routing 8 channels of AES/EBU and 8 channels of SMUX2 ADAT digital audio to and from the host system.
Hardware 88192 A/D D/A Converter SYSTEM Nominal Sample Rates 44.1, 48, 88.2, 96, 176.4, and 192 kHz Sample Sync Range 30-200 kHz +/- 100 ppm Dynamic Range Analog (A/D and D/A): > 115 dB (20 Hz to 20 kHz, A-weighted) Digital: > 144 dB (SRC off) Frequency Response 20 Hz - 40 kHz @ sampling rates > 88 kHz (+/- 1.
Rear Panel User’s Guide REAR PANEL ITEM DESCRIPTION DETAILS POWER INPUT IEC 3 prong jack Accepts power from detachable IEC power cable (100-240 VAC, 50-60 Hz, 45 Watts max). Connect only to a grounded power outlet. RS-232 Female DB9 Factory use only. ADAT I/O 4 x TOSLINK Digital inputs and outputs 1-8 in ADAT format on TOSLINK connectors. One TOSLINK pair handles up to 50 kHz sample rates, both pairs handle sample rates from 50-100 kHz in SMUX2 mode.
Hardware Connections 88192 A/D D/A Converter Hardware Connections POWER: Connect the IEC connector side of the supplied AC cord to the receptacle on the rear of the 88192. Connect the other side of the AC cable to an AC power source that is of the correct voltage and frequency (100-240 VAC, 50-60 Hz). Use only the power cord and connector specified for the product and your operating locale. Don’t forget to switch the power on, it will be the first question tech support asks of you if you call.
Basic Setup User’s Guide Basic Setup - Illustration Pressing the “exit” button while turning the encoder clockwise will enable the screen lock function. While in screen lock, no menus may be navigated and no parameters may be changed. To exit screen lock, hold the “exit” button while turning the encoder counter-clockwise. The following illustration details the connections (for option 1 digital connections) in a visual format.
Basic Setup 88192 A/D D/A Converter 8. Rotate the encoder to adjust the input gain for the selected input (1). The gain is adjusted in real time. 9. Push the encoder when finished to deselect the input. Basic Setup - Conclusion This concludes the basic setup. If you have followed the previous Basic Setup sections completely, you should have the correct hardware connections and the 88192 should be set up correctly.
Applications User’s Guide 88192 with the Digidesign 001/002 To ANALOG INPUTS Optical (Toslink) Cables From ANALOG OUTPUTS 88192 Setup Digidesign 001/002 Setup 1. In the “Route” menu, ensure that “Analog INs ADAT OUTs” and “ADAT INs Analog OUTs” are both shown. 1. In the Pro Tools software, open the “Hardware Setup” and set the “Clock Source” to “ADAT”. 2. In the “Sync” menu, select the desired internal sample rate. NOTE: the 001/002 hardware’s ADAT I/O only supports sample rates up to 48 kHz.
Applications 88192 A/D D/A Converter Applications - 88192 and Digidesign HD (192 Digital) To ANALOG INPUTS AES XLR to DB25 cable, Hosa DBK258 or similar From ANALOG OUTPUTS WORD CLOCK 88192 Setup Digidesign HD (192 Digital) Setup 1. In the “Route” menu, ensure that “Analog INs AES OUTs” and “AES INs Analog OUTs” are both shown. 1. In the Pro Tools software, open the “Hardware Setup” and set the “Clock Source” to “Word Clock”. 2. In the “Sync” menu, select the desired internal sample rate. 2.
Applications User’s Guide Applications - 88192 and RME Hammerfall HDSP 9652 To ANALOG INPUTS From ANALOG OUTPUTS Optical (Toslink) Cables 88192 Setup RME Hammerfall HDSP 9652 Setup 1. In the “Route” menu, ensure that “Analog INs ADAT OUTs” and “ADAT INs Analog OUTs” are both shown. 1. In the Hammerfall Control Panel, set the “Clock Mode” to “AutoSync” and set the “Pref Sync Ref” to “ADAT 1 In”. 2. In the “Sync” menu, select the desired internal sample rate. 2.
Applications 88192 A/D D/A Converter Applications - 88192 and MOTU 896HD, etc. To ANALOG INPUTS Optical (Toslink) Cables WORD CLOCK From ANALOG OUTPUTS 88192 Setup MOTU 896HD, etc. Setup 1. In the “Route” menu, ensure that “Analog INs ADAT OUTs” and “ADAT INs Analog OUTs” are both shown. 1. Configure the MOTU hardware to sync to its Word Clock input. 2. 2. In the “Sync” menu, select the desired internal sample rate.
Advanced Features User’s Guide Advanced Features NOTE 2: The Sync menu will display the incoming sync rate and the lock status. This can be very useful for diagnostics! The locked status, sample rate and sync source are also visible on the main status screen (see Appendix A, menu level 1). It is inevitable you will come across a setup which does not fit into the examples detailed within the Basic Setup or example Applications sections. For those cases, the 88192 has a few deeper settings to accommodate.
88192 A/D D/A Converter Appendix A - Hardware Menu Structure 0: Startup - Full screen startup graphic 2: Setup - Main Panel Control Functions and Default States ADAT: Jump to menu level 3 AES: Jump to menu level 4 ANALOG: Jump to menu level 5 METER: Jump to menu level 6 ROUTE: Jump to menu level 7 SYNC: Jump to menu level 8 SYSTEM: Jump to menu level 9 Panel Control Functions and Default States EXIT: Not Applicable ENTER: Not Applicable DIAL: Not Applicable DEFAULT: Not Applicable 1: Display - Centra
Appendix A - Hardware Menu Structure User’s Guide 4: Setup - AES 5.2: Setup - Analog Input Gain Toggle all 4 parameters ON/OFF All inputs can be individually set to MUTE, or at a GAIN levels from -95.5 to +31.
88192 A/D D/A Converter Appendix A - Hardware Menu Structure 6: Setup - Metering 7.
Appendix A - Hardware Menu Structure 8: Setup - Sync 9: Setup - Main INTERNAL: 44.1, 48, 88.2, 96, 176.4, 192 When Internal chosen, External becomes OFF, lights to indicate internal sync rate (30 - 200 kHz) LOCKED/UNLOCKED - when Internal chosen, lights to verify lock status MISCELLANY: Jump to menu level 9.1 RS-232: Jump to menu level 9.
88192 A/D D/A Converter Appendix A - Hardware Menu Structure 9.
Wiring Reference User’s Guide Balanced Connections NOTE: In the case of an XLR connector, the Female attaches to an output, while the Male attaches to an input. Any of these connectors can appear on either side of a balanced connection. Euroblock [balanced] Terminal Strip [balanced] Tip = (+) Plus Ring = (–) Minus Sleeve = Ground NOTE: Detachable Euroblock and Terminal Strip connectors are designed for use with bare wire. Do not tin stranded wires before inserting them into the connectors.
Wiring Reference 88192 A/D D/A Converter Unbalanced Connections: In this example, the unbalanced connector is sending signal to a balanced connector. When wiring this connection, use a shielded twisted pair cable. The balanced side wires the same as a standard, balanced connection. On the unbalanced side, you wire the white (minus) wire together with the ground. This provides some common mode rejection at the balanced input.
Statement of Conformity User’s Guide Declaration of Conformity We, Symetrix Inc., 6408 216th St. SW, Mountlake Terrace, Washington, USA, declare under our sole responsibility that the product: 88192 A/D D/A Converter to which this declaration relates, is in conformity with the following standards: EN 60065 Safety requirements for mains operated electronic and related apparatus for household and similar general use.
Warranty and Service 88192 A/D D/A Converter The Symetrix Limited Warranty If you have determined that your Symetrix product requires repair services and you live outside of the United States please contact your local Symetrix dealer or distributor for instructions on how to obtain service. If you reside in the U.S. then proceed as follows: Symetrix, Inc.
Item No. 53-0015 88192 A/D D/A Converter User’s Guide © 2009 Symetrix, Inc. All rights reserved. Printed in the United States of America. The information in this document is subject to change without notice. Symetrix, Inc. shall not be liable for technical or editorial errors or omissions contained herein; nor is it liable for incidental or consequential damages resulting from the furnishing, performance, or use of this material.