User`s guide
13
88192 A/D D/A Converter
Applications - 88192 and MOTU 896HD, etc.
To ANALOG INPUTS
From ANALOG OUTPUTS
WORD CLOCK
Optical
(Toslink)
Cables
88192 Setup
1. In the “Route” menu, ensure that “Analog INs ADAT OUTs” and
“ADAT INs Analog OUTs” are both shown.
2. In the “Sync” menu, select the desired internal sample rate. NOTE:
Most MOTU ADAT I/O supports sample rates up to 48 kHz for
8-channel and up to 96 kHz for 4-channels.
MOTU 896HD, etc. Setup
1. Configure the MOTU hardware to sync to its Word Clock input.
2. Configure your preferred audio software application to receive input
from the MOTU hardware’s ADAT INs.
3. Configure your preferred audio software application to output to the
MOTU hardware’s ADAT OUTs.
For more information or troubleshooting steps, please consult your
MOTU documentation or the support resources at
http://www.motu.com.