User`s guide
5
88192 A/D D/A Converter
Hardware
FRONT PANEL
ITEM DESCRIPTION DETAILS
DISPLAY Monochrome VFD Displays the current operational status, meters and configuration menus.
ADJUST Push button continuous Cycles through menu items or adjust menu item parameters. Push button functions rotary
encoder as a selector for menu item parameters, a confirm for menu item parameters or
a toggle for two-state parameters. (Refer to Appendix A for the menu structure.)
EXIT Momentary button Jumps to the main status screen or previous menu in the hierarchy. (Refer to Appendix A
for the menu structure.)
VENTS Patterned holes on each side of
the VFD
Provides ventilation for the unit. Do not obstruct!
POWER SWITCH Rocker switch Turns the unit off and on.
SYSTEM
Nominal Sample Rates 44.1, 48, 88.2, 96, 176.4, and 192 kHz
Sample Sync Range 30-200 kHz +/- 100 ppm
Dynamic Range Analog (A/D and D/A): > 115 dB (20 Hz to 20 kHz, A-weighted)
Digital: > 144 dB (SRC off)
Frequency Response 20 Hz - 40 kHz @ sampling rates > 88 kHz (+/- 1.0 dB)
THD + Noise < -105 dBA @ 1 kHz, -1 dBFS A/D; < -95 dBA @ 1 kHz, -1
dBFS D/A