13. MIDI Implementation Chart
13.1 Basic SysEx Format
Value
Name
F0h SysEx header
00h 20h 0Dh MIDITEMP manufacturer ID
65h Model ID (MADI Bridge)
00h..7Eh, 7Fh Device ID. 7Fh = broadcast (all IDs)
mm Message type
nn Parameter number (see table 1)
oo Databyte
F7h EOX
13.2 Message Types
Value
Name
10h Request value
20h Set value
30h Value response
Request Value
Format: F0 00 20 0D 65 (dev ID) 10 F7
This string triggers a complete dump of all value response data bytes.
Value Response
After being triggered by receiving a request value command, device sends a string of all value
response data bytes. Message type is set to 30h.
Set Value
Sets any number of parameters.
nn / oo can be repeated freely.
13.3 Total Reset
Sending the following SysEx string to the MADI Bridge will perform a complete reset (factory
default state). Device ID is set to 00, all presets are set to 0 (no connection active in any pre-
set), and preset NONE is selected.
F0 00 20 0D 65 7F 20 0A 00 05 00 07 01 05 01 06 01 05 02 06 01 05 03 06 01 05 04 06 01 05
05 06 01 05 06 06 01 05 07 06 01 05 08 06 01 05 09 06 01 05 0A 07 01 F7