User`s guide

User's Guide MADI Bridge © RME
17
13.4 Table
No. Name
Request
Value
Set
Value
Value
Response
Data bytes
05h Preset number x x x
1 Byte, value 0..10 (0..9 = Preset number,
0A = Matrix real-time display)
06h Store x 1 = set
07h Recall x 1 = recall
08h Key Lock x x
09h MIDI Lock x x
0Ah Device ID x x x 1 Byte (00h..7Eh, 7Fh = broadcast)
10h Preset 1 Out 1 x x
1 Byte, value 0..8
(0 = no input, 1..8 = input number)
11h Preset 1 Out 2 x x Same
12h Preset 1 Out 3 x x Same
13h Preset 1 Out 4 x x Same
14h Preset 1 Out 5 x x Same
15h Preset 1 Out 6 x x Same
16h Preset 1 Out 7 x x Same
17h Preset 1 Out 8 x x Same
18h Preset 2 Out 1 x x Same
19h Preset 2 Out 2 x x Same
1Ah Preset 2 Out 3 x x Same
1Bh Preset 2 Out 4 x x Same
1Ch Preset 2 Out 5 x x Same
1Dh Preset 2 Out 6 x x Same
1Eh Preset 2 Out 7 x x Same
1Fh Preset 2 Out 8 x x Same
20h Preset 3 Out 1 x x Same
21h Preset 3 Out 2 x x Same
22h Preset 3 Out 3 x x Same
23h Preset 3 Out 4 x x Same
24h Preset 3 Out 5 x x Same
25h Preset 3 Out 6 x x Same
26h Preset 3 Out 7 x x Same
27h Preset 3 Out 8 x x Same
28h Preset 4 Out 1 x x Same
29h Preset 4 Out 2 x x Same
2Ah Preset 4 Out 3 x x Same
2Bh Preset 4 Out 4 x x Same
2Ch Preset 4 Out 5 x x Same