User`s guide
22
User’s Guide Micstasy © RME
11.7 Follow Clock (FC)
Default: Off
Available settings: On, Off
The signal at the word clock or AES input can be Single, Double or Quad Speed, the Micstasy
can use it in any case, independent of its current clock range. When activating the option Follow
Clock the Micstasy follows the input clock 1:1. At 96 kHz the DS LED will light up automatically,
at 192 kHz the QS LED. This function is automatically deactivated for the I64 MADI Card, as it
is not possible to detect the sample rate range of the MADI-embedded audio data.
11.8 Peak Hold (PH)
Default: Off
Available settings: On, Off
The level meter can be configured to hold the peak value permanently. A reset is done by turn-
ing the Encoder, also when no other function had been selected before.
11.9 AutoSet Downlink (AS dL)
Default: None
Available settings: Channel 2 up to 8 via Select key
The AutoSet feature would not be complete without a way to link several channels to avoid
changes of volume (surround) or panorama (stereo).
AutoSet can be linked with one or more channels to the left of any given channel. After activat-
ing AS dL in the Setup menu, the seven Select buttons are used for configuration. The following
three examples will illustrate this:
• Select channel 5, the blue AutoSet LED of channel 5 lights up. Channels 4 and 5 are now
linked.
• Select channels 5 and 4. The AutoSet LEDs for channels 5 and 4 light up. Channels 5, 4,
and 3 are linked.
• Select channels 8 and 7. The AutoSet LEDs for channels 8 and 7 light up. Channels 8, 7 and
6 are linked. This 'group' will operate independently of the other group (5/4/3).
Thus, up to 4 independent stereo pairs and two groups of multiple channels can be set up, all of
which will work independently.
When leaving the AutoSet menu and selecting AutoSet, the LEDs of all channels with active
AutoSet will light up. The only way to determine whether channels are linked or not is to open
the Setup menu.
Even when Downlink is activated, the values determined by AutoSet can be changed manually
without changing relative levels. To do so, all linked channels must be selected when changing
gain.