User Manual

User's Guide MADIface XT © RME
41
19.5 Setup Menu
SETUP offers several options to configure the device. Encoder 1 changes between Options and
Setups. The sub-menus in Options, General Settings, Digital Routing, Clock and MIDI Sources,
are accessed with encoder 2.
19.5.1 Options Menu
The page Clock has the following entries:
Clock Source
Only adjustable in stand-alone mode! Choices are INT (Internal, Master), WCK (word clock),
AES, MADI 1 to 3.
Sample Rate
Choices are 32, 44.1, 48, 64, 88.2, 96, 128, 176.4 and 192 kHz.
Setting the correct sample rate is even necessary in slave mode,
with external clocking via word or one of the digital inputs. Only
with AES the real current sample rate can be detected. With
MADI the user has to inform the unit, whether the input signal is
in the single, double or quad speed range.
WCK Alw. Singl
Word Clock Always Single Speed. Choices are On or Off.
WCK Term.
Word clock termination for the word clock input – On or Off.
These options are explained in detail in chapter 19.6.
The page Hardware Diagnosis has the following entries:
AES State Pro
On – channel status Professional. Off – channel status Consumer.
Standalon. MIDI
Device reacts on MIDI commands when in stand-alone mode: On
or Off.
Interface Mode
Available options: Auto, PCIe, USB 3, USB 2. In USB 2 mode the
number of transmitted channels is reduced to 70.
LCD Contrast
Adjusting the contrast of the display.
Test Results
Please ignore. No user related data.
SW Version
Shows the current version number and date of the internal DSP software.