25.8.3 OSC Page
The OSC page has four independent settings for up to four MIDI remote controls via Open
Sound Control (OSC). This is a network based remote protocol that can be used for example by
Apple’s iPad with the app TouchOSC or Lemur to wirelessly remote control TotalMix FX running
on a Mac or Windows computer.
Index
Select one of four settings pages and thus remote controls. Settings are remembered automati-
cally. To activate or deactivate any of the four remote controls check or uncheck ‘In Use’.
TotalMix FX OSC Service
¾ IP. Shows the network address of the
computer running TotalMix FX (local
host). This address must be entered
on the remote side.
¾ Host Name. Local computer name.
¾ Port incoming. Must match the
remote entry ‘Port outgoing’. Typical
values are 7001 or 8000.
¾ Port outgoing. Must match the remote
entry ‘Port incoming’. Typical values
are 9001 or 9000.
Remote Control
¾ IP or Host name. Enter the IP or host
name of the remote control. Please
note that the IP number usually works
better than the host name.
Options
¾ Send Peak Level. Activates the
transmission of the peak level meter
data. Peak Hold activates the peak
hold function as set up for the TotalMix
level meters in the preferences.