5.0 Specification
No Item Class I Class II Class III Measuring Condition
10
Resistance
to
Soldering
heat
C
2.5or 0.25pF
Whichever is greater
Y5P 5
Z5U 15
Z5V 20
Y5P : ± 7.5%
The lead wire is immersed in the melted
solder 1.5mm to 2mm from the capacitor
body
(Class I, II)
Solder temperature350 10
Duration3 0.5sec.
(Class III)
Solder temperature260 5
Duration5 0.5sec.
The measurements after testing must be
taken after leaving the sample for 12 to
24 hours under normal temperature and
humidity conditions.
Withstanding
voltage
No defects
Exterior No abnormalities
11
Temperature
and
Immersion
cycling
C
5or 0.5pF
Whichever is greater
Y5P : ± 15 %
Fix the capacitor to the supporting jig in
the same manner and under the same
conditions as (10). Perform the 5 cycles
according to the four heat treatments
listed in the following table.
QD.F.
C30pFQ350
10pF>C<30pF
Q275 +
2
5
× C
C10pFQ200 + 10 × C
(C is nominal capacitance)
Y5P &Z5U
tanδ 0.05
Z5V
tanδ 0.075
Y5Ptanδ 0.05
I.R.
More than 1GΩ
More than 1GΩ or 20M Ω
F,whichever is less.
More than 500MΩ or 10M Ω
F,whichever is less.
Withstanding
voltage
No defects
Exterior No abnormalities
12
Humidity
Loading
C
7.5or 0.75pF
Whichever is greater
Y5P 10
Z5U 20
Z5V 30
Y5P : ± 15 %
Temperature40 2
Humidity90 to 95R.H.
Duration500
0
24
hrs.
The rated voltage continuously applied.
The chargedischarge current is less
than 10mA.
The measurements after testing
must be taken after leaving the
sample for 1 to 2 hours under normal
temperature and humidity conditions.
Perform a heat treatment at 40 2
for 1 hour. Remove and let sit for 1 to 2
hours at normal temperature and
humidity conditions. Perform the initial
measurement.
QD.F.
C30pFQ200
C<30pF
Q100 +
3
10
× C
(C is nominal capacitance)
Y5P &Z5U
tanδ 0.05
Z5V
tanδ 0.075
Y5P tanδ
0.075
I.R.
More than 1GΩ
More than 1GΩ or 20M Ω
F,whichever is less.
More than 500MΩ or 10M Ω
F,whichever is less.
Withstanding
voltage
No defects
Exterior No abnormalities
Step 1 2 3 4
Temp.
()
Min.
Operating
Temp.
Room
Temp.
Max.
Operating
Temp.
Room
Temp.
Time
(min.)
303 15 303 15
The measurements after testing must be
taken after leaving the sample for 12 to
24 hours under normal temperature and
humidity conditions.
Y5P 10
Z5U 20
Z5V 30