Datasheet
Ceramic Disk Capacitors
No Item Class I Class II Class III Measuring Condition
13
Life
C
5﹪or 0.5pF
Whichever is greater
Y5P: 10﹪
Z5U: 20﹪
Z5V: 30﹪
Y5P : ± 15 %
Applied voltage:
Rated voltage ×2(Class I, II)
Rated voltage ×1.25(Class III)
Temperature:85 2℃
Duration:1000
0
48
hrs.
The chargedischarge current is less than
10mA.
The measurements after testing must be
taken after leaving the sample for 12 to
24 hours under normal temperature and
humidity conditions.
Perform a heat treatment at 85 2℃
for 1 hour. Remove and let sit for 12 to 24
hours at normal temperature and
humidity conditions. Perform the initial
measurement.
Q╱D.F.
C≧30pF:Q≧350
10pF>C<30pF:
Q≧275 +
2
5
× C
C≦10pF:Q≧200 + 10 × C
(C is nominal capacitance)
Y5P & Z5U:
tanδ ≦0.05
Z5V:
tanδ ≦0.075
Y5P: tanδ
≦0.075
I.R.
More than 1GΩ
More than 1GΩ or 20M Ω ‧
F,whichever is less.
More than 500MΩ or 10M Ω
‧F,whichever is less.
Withstanding
voltage
No defects
Exterior No abnormalities
* Note on standard condition:“standard condition”referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85﹪relative humidity, and 860 to 1060 mbar of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 23℃ 2℃ of temperature, 60 to 70﹪relative humidity, and 860 to 1060
mbar of air pressure, unless otherwise specified, all the tests are conducted under the“standard condition”.
6.0 Storage
1. The storage conditions should be:
Temperature = Lower than 40℃
Humidity = Lower than 70% R.H.
2. After opening the package, please store in desiccators.
5.0 Specification
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com