Datasheet

Ceramic Disk Capacitors
No Item Class I Class II Class III Measuring Condition
13
Life
C
5or 0.5pF
Whichever is greater
Y5P 10
Z5U 20
Z5V 30
Y5P : ± 15 %
Applied voltage
Rated voltage ×2(Class I, II)
Rated voltage ×1.25(Class III)
Temperature85 2
Duration1000
0
48
hrs.
The chargedischarge current is less than
10mA.
The measurements after testing must be
taken after leaving the sample for 12 to
24 hours under normal temperature and
humidity conditions.
Perform a heat treatment at 85 2
for 1 hour. Remove and let sit for 12 to 24
hours at normal temperature and
humidity conditions. Perform the initial
measurement.
QD.F.
C30pFQ350
10pF>C<30pF
Q275 +
2
5
× C
C10pFQ200 + 10 × C
(C is nominal capacitance)
Y5P & Z5U
tanδ 0.05
Z5V
tanδ 0.075
Y5P tanδ
0.075
I.R.
More than 1GΩ
More than 1GΩ or 20M Ω
F,whichever is less.
More than 500MΩ or 10M Ω
F,whichever is less.
Withstanding
voltage
No defects
Exterior No abnormalities
* Note on standard condition“standard condition”referred to herein is defined as follows
5 to 35 of temperature, 45 to 85relative humidity, and 860 to 1060 mbar of air pressure.
When there are questions concerning measurement results
In order to provide correlation data, the test shall be conducted under condition of 23 2 of temperature, 60 to 70relative humidity, and 860 to 1060
mbar of air pressure, unless otherwise specified, all the tests are conducted under the“standard condition”.
6.0 Storage
1. The storage conditions should be:
Temperature = Lower than 40
Humidity = Lower than 70% R.H.
2. After opening the package, please store in desiccators.
5.0 Specification
Distrelec Schweiz AG, Grabenstrasse 6, 8606 Nänikon, Switzerland, T +41 44 944 99 11, info@distrelec.com, distrelec.com