Datasheet

EMI Filter 10A
Drawing
Specification
Voltage Rating
115 / 250 VAC
Current Rating - A @ 115 VAC 10 A RMS Max.
Operating Frequency 50 / 60 Hz
Leakage Current: Each Line to Ground - A @ 115 VAC / 60 Hz
0.4 mA max.
Leakage Current: Each Line to Ground - B @ 250 VAC / 50 Hz 0.8 mA max.
Hipot Rating - A - Line to Ground
2250 VDC
Current Rating - B @ 250 VAC 10 A RMS Max.
Operating Temperature Min. -25 °C
Operating Temperature Max. 85 °C
IR 50 MOhm @ 500 VDC Any Input or Output to Ground
Hipot Rating - B - Line to Line 500 VDC
Electrical Schematic
Art Nr.
RND 165-00167
Features
RND filters are designed for easy and fast chassis mounting
High conducted attenuation performance
Terminals for easy assembly
Applications
Electrical and electronic equipment / power systems
Datacom equipment / stepper motor drives
Stepper motor drives / UPS and inverters