Datasheet

4.1 Open circuit voltage and closed circuit voltage (Load resistance 150Ω, 0.3s)
/
OCV(V) CCV(V)
Initial
Min 9.3 8.7
Normal 10.2 10.05
Stored 1 year
Min 9.3 8.7
Normal 10.2 10.05
4.2 Service Output
Load 60 270Ω 62
Background:
10 000
a
Pulse:620
Test mode 24h/d 1h/d 2h/d
24h
1 s per h
end voltage 5.4V 7.8V 7.8V 7.8V
Unit hour hour hour day
Initial
M.A.D 54 20.5 47 36
Normal 58 22.5 51 39
Stored
1 year
M.A.D 53.5 20.2 46.5 35.6
Normal 57.5 22.2 50.5 38.6
a: Smoke detector test. This is an accelerated test. (The pulse load of 62 alone should be applied across the
battery. It is not added in series or parallel to the 10000Ω background load.)
*The initial discharge test shall commence within 30 days of manufacture. During stored period, the cells shall be
stored under room temperature conditions.
5. Reliability Test
5.1 High Temperature Test
1.1.1 Store the cells in the temperature chamber at 60 for 30 days, any defects should not be
observed in appearance and dimensions.
1.1.2 Store the cells in the temperature chamber at 70 for 10 days, any defects should not be
observed in appearance and dimensions.
5.2 Low Temperature Test
Store the cells in the temperature chamber at -30 for 10 days, any defects should not be
observed in appearance and dimensions.
5.3 High Temperature and Humidity Test
Store the cells in the temperature & humidity chamber at 60, 90%RH for 30 days, any
defects should not be observed in appearance and dimensions.
RND is a trademark of Distrelec
Primary Lithium Battery
RND 305-00004E