Datasheet

Voltage Tester
RND is a trademark of Distrelec
Features
Complies with EN 61243-3:2014
LED indication range: 12 V to 1000 V dc and ac
Independent ELV indicator LED, indicates if >50 V ac/120 V dc is present even in the event of no
battery power or main circuit failure
LCD indication range: 6 V to 1000 V dc and ac
Resistance measurement: LCD 3½ digit (0 to 1999 Ω/1Ω resolution)
LCD backlight display HOLD: Freeze/unfreeze display with voltage or resistance measurement
Rugged, double-insulated wire
Fixed impedance ~300 kΩ (≤3.5 mA @ 1000 V)
Switchable load by 2 pushbuttons (30 mA @ 230 V)
Single-pole phase test (also operates with gloves)
Rotary field direction (also operates with gloves)
Continuity test / diode Test
Flashlight
Beeper for continuity/phase/ACV
19 mm probe tip distance when docked
CAT III 1000 V / CAT IV 600 V
IP64 rating
Specification
12 V to 1000 V AC / DC
Resolution ±12 V, 24 V, 50 V, 120 V,230 V, 400 V, 690 V, 1000 V
Frequency Range 0 / 40 Hz to 400 Hz
Response Time
≤0.5 second
Auto Power ON ≥12 V AC / DC
Tolerance Complies with EN 61243-3:2014
LEDs
Voltage Range
6 V to 1000 V AC / DC
Resolution ±1 V
Frequency Range 0 / 40 Hz to 400 Hz
Response Time
≤1 second
Auto Power ON ≥6 V AC / DC
Voltage Detection
Automatic
Tolerance ±(3 % rdg + 5 digits)
Range Detection Automatic
Internal Basic Load Impedance Peak Current Maximum 3.5 mA at 1000 V 300 kΩ / Is <3.5 mA (no RCD tripping)
Operation Time Duration Time = 30 Seconds
Polarity Detection Full Range
Voltage Range
LCD
Switchable Load ~7 kΩ
Peak Current
Is (load) = 150 mA
RCD Tripping I=30 mA @ 230 V
Continuity Test
0 to 400 kΩ
Recovery Time 240 seconds
Test Current ≤5 μA
Single-Pole Phase Test 100 V ac to 1000 V ac
Frequency Range
40 Hz to 60 Hz
Accuracy Nominal Resistance +50 %
EN
61010-1
CAT III
1000V
EMC & LVD
EN: 61326
EN: 61010-1
EN: 61243
EN: 61010-3

Summary of content (2 pages)