Safety Instructions

10
until the battery voltage reaches 14.4V. Then, the battery is charged at a constant voltage of
14.4V while tapering the charge current. The standard charging process is considered com-
plete when the charge current is less than 10A. However, leaving the battery on oat will con-
tinue to balance the battery cells and will not damage the battery. The standard charging pro-
cess normally takes 5.5 hours. Safe charging requires battery temperatures between 32°F and
131°F (0°C and 55°C).
Discharging Battery
DO NOT exceed the maximum continuous discharge current of the battery.
DO NOT connect large loads to the battery when it is running low
If the battery shuts o󰀨 due to low state of charge (SoC), please disconnect the battery from
loads and charge the battery as soon as possible. Failure to do so may cause irreversible
damage to the battery.
It is recommended to pair the battery with discharge equipment featuring low voltage dis-
connect.
During the standard discharging process, the battery is discharged at a constant current of 60A
until the battery voltage reaches 10V. Safe discharging requires battery temperatures between
-4°F and 140°F (-20°C and 60°C).
Battery Maintenance
Inspection
Please perform regular inspections following the steps below:
Examine the external appearance of the battery. The top of the battery and terminals should
be clean, dry, and free of corrosion.
Check battery cables and connections. Replace any damaged cables and tighten any loose
connections.
Terminal corrosion may adversely a󰀨ect the battery performance and present a safety haz-
ard. Please keep terminals free of corrosion.
Cleaning
Please clean the battery at regular intervals following the steps below:
Disconnect the battery from the charging source and/or loads.