Operating instructions

Functions:
Input:
10.5…18 V DC (user-variable low voltage
alarm, 11…12 V)
or 100…240 V AC (plug-in lead with On / Off
switch)
2 x 0.1…20 A charge current (max. 200 W
per output - 12 V or 230 V)
2 x 0.1…10 A discharge current (max. 40
W per output)
USB charge socket, 5 V / 1 A for smart-
phones and digital cameras
Internal resistance measurement
Internal device temperature display
2 x 20 internal battery data memories
Charge / discharge (cycle) – mode 1 - 10 x
with capacity display per cycle
Mini-USB socket for rmware upgrades
and future data output
Menu system can be set to German,
English, French or Italian.
Over-temperature guard
Current overload protection
Short-circuit protection
NC / NiMH batteries
2 x 1…18 NC / NiMH cells
Charge process: automatic, normal, linear
and reex methods
User-variable trickle charge current
(50…300 mA, off)
Variable peak sensitivity (3…15 mV / cell)
Variable pre-peak suppression (1…5 min.,
off)
Lithium batteries, LiIo (3.6 V), LiPo (3.7 V)
or LiFe (3.3 V)
2 x 1…7 Lithium cells - charge and dischar-
ge, cycle
Powerful balancer with 300 mA and
zero-current measurement
Selectable charge power, up to 5C (20 A)
User-variable maximum cell voltage
Safety timer cut-off (20...720 min., off)
Maximum capacity cut-off (0.1…60 Ah)
Storage mode (60%)
Fast-charge mode without balancing
function
Separate balancing program
0.1 Volt boost function for Lithium batteries.
Increasing the cut-off voltage by 0.1 Volt
provides approximately 10% more battery
capacity.
Lead-acid batteries
2 x 2…24 V lead-acid batteries - charge
and discharge
No. 8129
Data display: charge voltage curve
Data display: list of charged-in and dischar-
ged capacities in Cycle mode
Fast-charge mode: fast-charge mode without
balancer function, for ultra-rapid recharging
of about 90% of full capacity.
Pure battery balancing program
127