Version 1.
CitySource 96 (Single colour) Table of contents 1. Safety instructions ...................................................................................................................................................... 3 2. Fixture exterior view ................................................................................................................................................... 5 3. Installation ................................................................................................
CitySource 96 (Single colour) FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR CitySource 96 ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
CitySource 96 (Single colour) This fixture was designed for indoor and outdoor use. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts. The fixture body never must be covered with cloth or other materials. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
CitySource 96 (Single colour) 2. Fixture exterior view 1. Lens array 2. Radiator 3. Mounting bracket 4. Tilt-lock screw 5. Power cable 6. Data cable (DMX in/out) 7. Control buttons 8. LED display 9. Antenna Standard version Wireles DMX version 3. Installation Warning for wireless DMX version of the CitySource 96! The antenna must be instaled on the fixture to keep declared IP rating of the fixture! 3.
CitySource 96 (Single colour) IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury or damage to property.
CitySource 96 (Single colour) You can install a frost foil under the eggcrate top hat to get frost light output. 1. Disconnect the fixture from the mains. 2. Uninstall the eggcrate lens module . 3. Place the frost foil (6) under the the eggcrate top hat (7) and secure it by means of the four screws (1) and washers (3) on the front panel of the fixture. The dimension of the frost foil 154mm x 103mm, max. thickness= 0.5mm. The frost foil has to stand temperature of 85°C.
CitySource 96 (Single colour) 3.4 Installation of the barn-doors and top hat/half top hat You can install the barn-doors or top hat/half top hat to better define illuminated surface. 1. Disconnect the fixture from the mains. 2. Remove the eggcrate lens module 25°(2) by unscrewing the four M5x14 screws (1) with washers (3). 3.
CitySource 96 (Single colour) To build a DMX chain 1. Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain. 2. Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture. 3. Always connect the DMX output with the input of the next fixture until all fixtures are connected. Do not overload the link. Max. 32 fixtures may be connected on a DMX link.
CitySource 96 (Single colour) 3.7 Stand-alone operation The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture. To set the program to be played, see the "Stand-alone setting" (menu "St.AL."). "Stand-alone operation" can be applied to the single fixture or to multiple fixtures operating synchronously.
CitySource 96 (Single colour) 4. CitySource 96 (Single colour) - DMX protocol Version 1.
CitySource 96 (Single colour) 5. Control menu map Default settings=Bold print Menu Level 1 Menu Level 2 Menu Level 3 A001 dM.Ad. 001-512 MA.SL. d.AbL Menu Level 4 MASt. SLA InFo Poti. FuLL totL rSEt EcO totL rSEt DM.In. dim1 0-255 : tEMP. F.dim 0-255 Cur.t. boAr. LEdS Hi.tE. boAr. LEdS rSEt boAr. LEdS PErS VErS. IC1 dM.Pr. Mod.1 Mod.2 Mod.3 Mod.4 dISP. d.On On, Off d.Int. 20...
CitySource 96 (Single colour) Menu Level 1 Menu Level 2 Menu Level 3 tEM.U. °C, °F LOAd FuLL Menu Level 4 Menu Level 5 Menu Level 6 EcO In.Po. dim1 0-255 : F.dim 0-255 Stor. hOLd On, Off dFSE MAn.M. PrE.C. COL.1 CO.01..CO.03 : Man.C. dimr di.01...di.06 COL.1 0-255 : F.dim 0-255 tESt St.AL. Auto Off tESt PrG.1 : PrG.3 PLAY tESt PrG.1 : PrG.3 Edit PrG.1 St.01 P.End 1-68 : : COL.1 0-255 PrG.3 St.
CitySource 96 (Single colour) Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 S.tim. 0-25.5 sec CoPY SPEC. rdML rdMH Adj. DMH dim1 : F.dimr CaL.U. COL.1 : COL.8 Stor. rAdI* r.InF. No.LI (0-100) r.UnL. uPd. * Only for wireless DMX version 6. Fixture menu The control panel menu allows to set the fixture according to your needs, obtain information on its operation, test its various parts and lastly program it, if it has to be used in a Stand-alone mode.
CitySource 96 (Single colour) 4. Press the ENTER button to confirm the choice. MA.SL. --- Master/slave addressing. Select this submenu to set the fixture as a master or slave. Option "d.AbL" deactivates master/slave setting. To set a fixture as a master or slave. 1. Use the UP/DOWN buttons to find “A001“ menu. 2. Press the ENTER button. 3. Use the UP/DOWN buttons to select “ MA.SL.“ item. 4. Press the ENTER button. 5. Use the UP/DOWN buttons to select either master (MASt) or slave (SLA) 6.
CitySource 96 (Single colour) Measuring points: LEdS.--- the temperature of the LEDs module. boAr. --- the temperature on the PCB in the fixture base. The temperatures can be displayed in either °C or °F units - see option “tEM.U“ in the menu “Pers“. VErS. ---Software Versions. Select this function to read the software version of the fixture processor. 6.3 Personality Use this menu to modify the CitySource 96operating behaviour. DM.Pr. --- DMX preset. Select this menu item to set a desired DMX mode.
CitySource 96 (Single colour) List of control channels: “COL.1” - LEDs saturation-array1 “COL.2“ - LEDs saturation-array2 “Stro.“ - a strobe, shutter “dimr“ - a dimmer “F.dim” – a fine dimmer 4. Press the ENTER button and use the UP/DOWN buttons to set value , press the ENTER button to confirm it. 6. 5 Test sequences Use this menu to run demo-test sequences without an external controller, which will show you some possibilities of using the CitySource 96. 6.
CitySource 96 (Single colour) 3. Use the UP/DOWN buttons to select a program you want to edit (PrG.1-PrG.3 and press ENTER button. 4. Use the UP/DOWN buttons to select a desired program step ("St.01" - "St.68") and press ENTER button. 5. Use the UP/DOWN buttons to select a channel you want to edit and press the ENTER button. List of editable items: “P.End” - a total number of the program steps (value 1-68). This value should be set before start Programming (e.g.
CitySource 96 (Single colour) 1. DMX Software Uploader program is available from the ROBE web site at WWW.robe.cz. 2. Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it. 3. Unpack the program from the archive. . II.Fixture software updating. 1. Determine which of your port is available on your PC and connect it: - with the DMX input of the fixture if you using the flash cable RS232/DMX - with the DMX input of the Robe Universal Interface if you using the USB cable.
CitySource 96 (Single colour) 7. RDM This fixture is ready for RDM operation.RDM (Remote Device Management) is a bi-directional communications protocol for use in DMX512 control systems, it is the new open standard for DMX512 device configuration and status monitoring. The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting existing non-RDM equipment.
CitySource 96 (Single colour) 8. Wireless DMX operation The wireless version of the CitySource 96 is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the 2.4 GHz band. To link the fixture with DMX transmitter. The fixture can be only linked with the transmitter by running the link procedure at DMX transmitter . After linking , the level of DMX signal ( 0-100 %) is displayed in the menu item “r.InF“ (SPEC-->rAdI.--> r.InF.
CitySource 96 (Single colour) • Manual control of all effects via control panel • 3 user editable programs each up to 68 steps Wireless DMX/RDM module (only for Wireless DMX version) • Compliance with USITT DMX-512 (1986 & 1990) and 512-A • Full DMX fidelity and frame integrity • Auto sensing of DMX frame rate and frame size • <5ms DMX latency • Operational frequency range of 2402-2480 MHz • Producer: LumenRadio Strobe • Strobe effect with variable speed (max.
CitySource 96 (Single colour) Wireless DMX version Removable floor stand Weight • 1.2 kg Protection factor • IP 65 (except DMX IN/OUT XLR connectors) Included items • 1 x CitySource 96 (City Source 96/W) • 1 x Eggcrate lens module 25° (No. 10980067) • 1 x omega holder (No. 99010420) • 1 x Removable floor stand (No.99512731) • 1 x User manual Optional accessories • 1 x Barn-dors (No.10980063) • Eggcrate lens module 45° (No. 10980068) • Eggcrate lens module 32°x 12° (No.
CitySource 96 (Single colour) • Single top-loader case (without castors) (No.10120085) • Dual top-loader case (No.10120087) • Quad top-loader case (No.10120086) • Flash cable RS232/DMX (No. 13050624) Note: By reason of the fast-moving development of LED technology, newer products may have better light parameters than previous products. 11. Cleaning and maintenance DANGER ! Disconnect from the mains before starting any cleaning or maintenance work Rinse off loose dirt with low pressure water spray.
CitySource 96 (Single colour) 25